A weighed sample, a sealed steel vessel full of oxygen, and a thermometer in the water around it. This bomb calorimeter simulator is a free interactive lab that turns that one reading into an answer per gram and per mole. It opens on the calibration run: 1.00 g of benzoic acid in 2000 g of water, a rise of 2.6422 °C, and the sub-line so Ccal = q / ΔT = 10.000 kJ/°C.
Now look at where that constant came from: 8.368 kJ/°C of water and 1.632 kJ/°C of steel, stirrer and thermometer, each on its own slider. Every other free tool on this topic hands you the constant and hides the two halves of it — and dropping the second half is the one mistake a plausibility check cannot catch.
A bomb is rigid, so no work is done and the heat it measures is the internal energy change, not the enthalpy change. The rise follows from Ccal = Chardware + mwatercwater, and the same three numbers give the calorimeter constant one way and the heat of combustion the other. The last step, ΔH = ΔU + ΔngasRT, is decidable from the formula — and for graphite it is exactly nothing.
Each button presses the lab’s own stage button, then its own sample button, then writes its three sliders, so every press lands on a known state. Every number you then see is the lab’s own, and the line underneath quotes the cards straight back to you.
The first is the calibration run every real determination starts with. The second and third are the two corrections that bound the answer. The last two are the pair this page is built around: the apparatus changes, the reading changes, and the answer does not.
Pick a run above, or drag the sliders yourself.

The bomb calorimeter simulator is a free interactive physics lab that runs in your browser, with nothing to install and no sign-up. On the left it draws the apparatus cut away — the dewar, the water jacket, the stainless-steel bomb submerged in it, the cup holding the weighed sample, the oxygen fill at about 30 atm, the stirrer, the ignition leads and a thermometer marked at the start and finish readings. On the right it draws a linear energy-density ladder in kJ/g carrying published reference values, with a marker at whatever the current burn gives.
Three sliders and six buttons drive it. Sample mass runs 0.20 to 1.50 g in steps of 0.01 and opens at 1.00 g; Water in the jacket runs 1500 to 2500 g in steps of 10 and opens at 2000 g; Bomb hardware runs 1.000 to 3.000 kJ/°C in steps of 0.001 and opens at 1.632 kJ/°C. Four buttons choose what is in the cup — benzoic acid, graphite, ethanol or propan-1-ol — and two more choose the stage, Calibrate or Measure.
Say plainly what this is: a forward model. The lab knows each sample's tabulated energy density and works out the rise that would follow, so the Measure stage is showing you the arithmetic a student does rather than discovering an unknown. Nothing on the screen is a measurement. It is honest about that because the whole value of the panel is that you can check every step of the chain against a figure you can look up.
Four cards carry the chain. The headline is the temperature rise to four significant figures, with the constant it came from underneath; then the heat, positive into the assembly, with the reaction's own negative figure beneath it; then per gram and per mole; then enthalpy from internal energy. At the opening setting they read 2.6422 °C, qcal = 26.422 kJ, qrxn = -26.422 kJ, ΔU = -26.422 kJ/g with -3226.76 kJ/mol, and ΔH = -3228.00 kJ/mol.
The quantity this lab exists to expose is the calorimeter constant, and here it is two sliders and a grid cell. At the opening setting the grid reads 10.000 kJ/°C, of which 8.368 kJ/°C is the water jacket and 1.632 kJ/°C is the steel, the stirrer and the thermometer. Drag the jacket to 2500 g and the constant becomes 12.092 kJ/°C and the rise falls to 2.1851 °C for the same gram of sample. Every other free tool on this topic hides that number inside the arithmetic.
Calibrate and Measure share one piece of arithmetic and swap which end of it is the answer. In Calibrate the cup is forced to benzoic acid, whose energy density is known, and the sub-line under the rise card reads so Ccal = q / ΔT = 10.000 kJ/°C. In Measure that constant is taken as settled and the sub-line flips to from Ccal = 10.000 kJ/°C, with the rise feeding the other three cards. The two buttons are coupled on purpose: pressing a sample other than benzoic acid while the stage is Calibrate moves the stage to Measure, because a calibration run on graphite is not a calibration.
Halving the sample halves the rise and leaves the answer alone, and that is the whole reason calibration works. Take the sample to 0.50 g and the rise falls to 1.3211 °C and the heat to qcal = 13.211 kJ, while the per-gram card still reads ΔU = -26.422 kJ/g and the per-mole line still reads -3226.76 kJ/mol. Enlarging the jacket does the same thing to the rise and leaves the same two figures untouched. The apparatus moves the reading; it does not move the substance.
The enthalpy card is where the step every textbook asks about is sized rather than asserted. With benzoic acid it reads Δngas = -0.5, correction = -1.2394 kJ/mol against a molar figure of -3226.76 kJ/mol. Press Graphite and the same sub-line reads Δngas = 0, so ΔH = ΔU exactly, with both cards on -393.50 kJ/mol — because burning carbon makes exactly as many moles of gas as it consumes, and that is decidable from the formula before any arithmetic starts.
A compact grid under the cards carries the constant and both of its terms, the amount n = m / M, the molar mass, the change in gaseous moles, the gross and net calorific values with the gap between them as a percentage, and the plausibility band. For ethanol the gross-and-net cell reads 29.7 gross, 26.7 net; gap 10.10 per cent; for graphite it reads 32.8 gross, 32.808 net; no water produced, so the difference is rounding, which is the cleanest demonstration of what that gap is that the panel can give.
A sentence under the drawings writes the current case out in full rather than repeating the cards, and the ladder on the right places the answer against published figures: benzoic acid at 26.43, methane at 55.52, coal at 15.00 and damp peat at 6.00 kJ/g, with hydrogen at 141.79 drawn as a labelled off-scale arrow because putting it on the axis would squash everything else into nothing.
What the lab leaves out, stated as omissions rather than as assumptions that happen to hold. There is no picture of the reading climbing to its final value, because the approach to a steady temperature belongs to a different topic and a different page. There are four samples and no box to type an unknown one into, and the three corrections a standard-compliant determination makes — the fuse wire, the acids formed from nitrogen and sulfur, the ignition energy — are named on the page and given no numeric value anywhere.
All four samples sit in the lowest of the published bands, at or below 33.6 kJ/g, so the higher bands on the ladder are bounds to read against rather than states these buttons can reach. Nothing here is measured: every digit is arithmetic on three slider positions and two button presses, so verify any figure against your own source before you use it.
| Control | Range | Step, default and what it moves |
|---|---|---|
| Sample mass | 0.20 to 1.50 g | steps of 0.01 g, opening on 1.00, where the read-back beside the slider says "1.00 g" and the spoken value repeats it. This is the control that moves the reading without moving the answer: at 0.20 g the rise card reads 0.5284 degrees Celsius and at 1.50 g it reads 3.9633, while the per-gram card holds at -26.422 kJ/g in every position and the per-mole line at -3226.76 kJ/mol. The published practical range is about 1 to 1.5 g, so the slider brackets it at both ends |
| Water in the jacket | 1500 to 2500 g | steps of 10 g, opening on 2000, which is the jacket volume the fetched apparatus description gives and the figure that makes the water term exactly 8.368 kJ per degree Celsius. It is one of the two halves of the calorimeter constant: at 1500 g the grid reads a constant of 7.908 and a rise of 3.3412 degrees, at 2500 g a constant of 12.092 and a rise of 2.1851. More water means a smaller rise for the same burn, and the same answer in kJ/g at the end of it |
| Bomb hardware | 1.000 to 3.000 kJ/°C | steps of 0.001, opening on 1.632, which is the steel, the stirrer and the thermometer and which corresponds to about 3.9 kg of stainless steel. It is the other half of the constant, and the half every ranking calculator on this topic omits. At its floor the constant is 9.368 and the rise 2.8205 degrees; at its ceiling, 11.368 and 2.3243. The slider cannot reach zero, so the water-only mistake is reachable on the calculator but not on this panel |
| Sample in the cup | four buttons | labelled Benzoic, Graphite, Ethanol and Propanol, with Benzoic pressed when the lab opens. Each swaps the tabulated energy density, the molar mass, the formula and the change in gaseous moles together, so the whole chain moves at once: one gram gives a rise of 2.6422, 3.2762, 2.9619 or 3.3551 degrees Celsius and a molar answer of -3228.00, -393.50, -1367.00 or -2020.00 kJ/mol. Graphite is the one with no correction to make. There is no fifth sample and no way to type one in |
| Stage | two buttons | labelled Calibrate and Measure, with Calibrate pressed at boot. Calibrate forces benzoic acid into the cup and reads the chain backwards, so the sub-line under the rise card gives the calorimeter constant from a known energy density; Measure takes that constant as settled and reads the chain forwards to kJ per gram and kJ per mole. The two groups are coupled: pressing any sample other than benzoic acid while the stage is Calibrate moves the stage to Measure, because a calibration run on graphite is not a calibration |
1.00 g of benzoic acid: Temperature rise 2.6422 °C, with so Ccal = q / ΔT = 10.000 kJ/°C under it; Heat qcal = 26.422 kJ over qrxn = -26.422 kJ; Per gram and per mole ΔU = -26.422 kJ/g over -3226.76 kJ/mol; and Enthalpy ΔH = -3228.00 kJ/mol.10.000 kJ/°C is Water term 8.368 kJ/°C plus Hardware term 1.632 kJ/°C, and the water half is the mass on the slider times the specific heat capacity of water, 4.184 J/(g·°C) — the figure the specific heat capacity of water guide settles on and explains the variants of.0.20 to 1.50 g the rise runs 0.5284 to 3.9633 °C and the heat card runs qcal = 5.284 kJ to 39.633 kJ. The per-gram and per-mole cards do not move at all. That is the first thing worth seeing on this panel.1.3211 and 2.1851 °C; and both leave ΔU = -26.422 kJ/g exactly where it was. The second also moves the constant to 12.092 kJ/°C, which is the water term going to 10.460.1.000 kJ/°C the constant reads 9.368 kJ/°C and the rise 2.8205 °C; at 3.000 they read 11.368 kJ/°C and 2.3243 °C. The slider stops at 1.000 and cannot reach zero, so the panel will not let you make the water-only mistake by accident — the bomb calorimeter calculator is where you can type it in and see what it costs.Δngas = 0, so ΔH = ΔU exactly, and both molar figures read -393.50 kJ/mol. Nothing was neglected and nothing was rounded away: burning carbon makes exactly as many moles of gas as it consumes.29.7 gross, 26.7 net; gap 10.10 per cent, and ΔH = -1367.00 kJ/mol above it. The gap is the energy given up when the water the burn made condenses inside the vessel, which is the quantity the latent heat guide is about.3.3551 °C, ΔU = -33.551 kJ/g and ΔH = -2020.00 kJ/mol, with Δngas = -1.5, correction = -3.7182 kJ/mol. Its gross-and-net cell reads 33.6 gross, 30.68 net; gap 8.69 per cent.83.68 per cent; with the hardware slider at 3.000 it falls to 73.61 per cent.Dragging is the right way to find out which readings move together and a poor way to land on a particular state, because the hardware slider alone has two thousand positions. The five preset buttons above exist for that, and the bomb calorimeter equation guide is where the subject itself is argued from scratch, with the chain derived step by step and the problems worked.
What this panel cannot do is start from numbers you measured yourself. It has no input box, four samples and no fifth, so a question that hands you a rise and a mass and asks for a molar mass — or hands you an enthalpy and asks what rise it would have produced — belongs to the bomb calorimeter calculator, which rearranges the same chain in five directions and prints the working for each.
2.6422 °C and its sub-line runs the chain backwards to Ccal = 10.000 kJ/°C, which is the only stage in which the apparatus is the answer. The ladder on the right marks the burn at the value its own caption gives, 26.42, which at this scale is indistinguishable from the published constant-pressure tick beside it at 26.43 — the same substance, measured two ways, each labelled. The canvas writes C_cal and T_f in ASCII, because a drawing surface has no markup to make a subscript with.Nothing in the four tables below was worked out here. Each row is a state the lab was put into through its own buttons and sliders and then read back from, cell by cell, and a reading is quoted whole rather than tidied: the heat card keeps its label, the per-gram card keeps its minus sign, and the gross-and-net cell keeps the clause that says why benzoic acid has no net figure.
Three kinds of cell are shortened to fit their column, and all three are declared here: the band cell to its number, the enthalpy column to its value without its sub-line, and the per-gram columns of the last two tables to the figure without the symbol the card prints in front of it.
The left-hand column is one gram of benzoic acid in Measure on the default apparatus. The middle column halves the sample and touches nothing else; the right-hand column leaves the sample alone and adds 500 g of water. Read the Temperature rise row and the Per gram row together, because that contrast is the entire argument for calibrating anything.
| Reading on the panel | One gram, standard jacket | Half the sample | Bigger jacket | What moved, and why |
|---|---|---|---|---|
| Sample mass chip | 1.00 g |
0.50 g |
1.00 g |
the only control the middle column touches |
| Jacket chip | 2000 g |
2000 g |
2500 g |
the only control the right-hand column touches |
| Water term | 8.368 kJ/°C |
8.368 kJ/°C |
10.460 kJ/°C |
the jacket’s share of the constant, and the only part a water slider can move |
| Constant Ccal | 10.000 kJ/°C |
10.000 kJ/°C |
12.092 kJ/°C |
the hardware term stays 1.632 kJ/°C in all three |
| Temperature rise card | 2.6422 °C |
1.3211 °C |
2.1851 °C |
all three differ. Less sample, or more to warm, means a smaller reading |
| Heat card | qcal = 26.422 kJ |
qcal = 13.211 kJ |
qcal = 26.422 kJ |
halving the sample halves the heat; enlarging the jacket does not touch it |
| Heat of the reaction | qrxn = -26.422 kJ |
qrxn = -13.211 kJ |
qrxn = -26.422 kJ |
the same magnitude with the sign the convention gives it |
| Amount burned | 0.00818847 mol |
0.00409423 mol |
0.00818847 mol |
follows the mass, because the molar mass is a property of the substance |
| Per gram card | ΔU = -26.422 kJ/g |
ΔU = -26.422 kJ/g |
ΔU = -26.422 kJ/g |
identical in all three. This is the answer, and the apparatus cannot move it |
| Per mole line | -3226.76 kJ/mol |
-3226.76 kJ/mol |
-3226.76 kJ/mol |
identical, because it is the per-gram figure times a molar mass |
| Enthalpy card | ΔH = -3228.00 kJ/mol |
ΔH = -3228.00 kJ/mol |
ΔH = -3228.00 kJ/mol |
identical, and equal to the published figure the sample table was built from |
| Plausibility band | band 0 |
band 0 |
band 0 |
the same class of fuel, because it is the same substance |
Three states, three different thermometer readings, and one number in the bottom half of the table that never moves. That is what a calorimeter constant buys you. Once the assembly has been calibrated, the reading it gives is a property of the apparatus and the sample together, while the figure you quote is a property of the substance alone.
It also sets the limit of what a reading on its own is worth. A rise of 2.1851 °C means -26.422 kJ/g in the right-hand column and would mean something else entirely in a different assembly, so a rise quoted without its constant is not a measurement of anything. That is why Calibrate is a stage rather than a footnote, and why the calculator version of this chain keeps the constant as one of its five solve directions.
Benzoic acid in Measure, the jacket at 2000 g and the hardware at 1.632, with only the mass slider moving. Note that the 0.20 g row is the floor of this slider on this apparatus, not the smallest rise the lab can produce: the rise falls with the two apparatus terms as well, and the swept minimum across every combination is 0.3926 °C.
| Sample mass slider | Temperature rise card | Heat card | Amount burned | What the reading shows |
|---|---|---|---|---|
| 0.20 g | 0.5284 °C |
qcal = 5.284 kJ |
0.00163769 mol |
the floor of this slider, and the smallest rise this apparatus gives |
| 0.25 g | 0.6606 °C |
qcal = 6.606 kJ |
0.00204712 mol |
a quarter more sample, a quarter more rise, to four figures |
| 0.50 g | 1.3211 °C |
qcal = 13.211 kJ |
0.00409423 mol |
the fourth preset: exactly half the rise of the 1.00 g row |
| 0.75 g | 1.9817 °C |
qcal = 19.817 kJ |
0.00614135 mol |
three quarters, and the heat card is the rise with the point moved |
| 1.00 g | 2.6422 °C |
qcal = 26.422 kJ |
0.00818847 mol |
the reference state, and the one the calibration preset uses |
| 1.25 g | 3.3028 °C |
qcal = 33.028 kJ |
0.0102356 mol |
past the gram, and still exactly in step |
| 1.50 g | 3.9633 °C |
qcal = 39.633 kJ |
0.0122827 mol |
the top of the slider, and the top of the published practical range |
The rise and the heat are in strict proportion to the mass down that table, and the per-gram card holds at -26.422 kJ/g in every one of the seven rows. The heat card is the rise with the decimal point moved, which is the constant being exactly 10.000 kJ/°C rather than a coincidence; change the jacket and that tidy relation disappears while the per-gram figure stays.
Now the sample stays at one gram of benzoic acid and the two apparatus sliders move instead. The first five rows walk the jacket from end to end with the hardware fixed; the last three walk the hardware with the jacket fixed. The final column is the same string eight times, and that is the result rather than a formatting accident.
| Apparatus setting | Water term | Hardware term | Constant | Temperature rise card | Per gram card |
|---|---|---|---|---|---|
| Jacket 1500 g | 6.276 kJ/°C |
1.632 kJ/°C |
7.908 kJ/°C |
3.3412 °C |
-26.422 kJ/g |
| Jacket 1750 g | 7.322 kJ/°C |
1.632 kJ/°C |
8.954 kJ/°C |
2.9509 °C |
-26.422 kJ/g |
| Jacket 2000 g | 8.368 kJ/°C |
1.632 kJ/°C |
10.000 kJ/°C |
2.6422 °C |
-26.422 kJ/g |
| Jacket 2250 g | 9.414 kJ/°C |
1.632 kJ/°C |
11.046 kJ/°C |
2.3920 °C |
-26.422 kJ/g |
| Jacket 2500 g | 10.460 kJ/°C |
1.632 kJ/°C |
12.092 kJ/°C |
2.1851 °C |
-26.422 kJ/g |
| Hardware 1.000 | 8.368 kJ/°C |
1.000 kJ/°C |
9.368 kJ/°C |
2.8205 °C |
-26.422 kJ/g |
| Hardware 2.000 | 8.368 kJ/°C |
2.000 kJ/°C |
10.368 kJ/°C |
2.5484 °C |
-26.422 kJ/g |
| Hardware 3.000 | 8.368 kJ/°C |
3.000 kJ/°C |
11.368 kJ/°C |
2.3243 °C |
-26.422 kJ/g |
The hardware term is between a tenth and rather more than a quarter of the constant across that table, and it is the term every ranking calculator on this topic leaves out. Leaving it out does not produce an absurd answer, which is exactly the problem: the reference run in this cluster gives 22.110 kJ/g against a true 26.422, which is 16.3 per cent low and still inside a plausible band.
The water half is the only part a reader can usually weigh directly, and it is the mass on the slider multiplied by the specific heat capacity of water. If that product is the step you want to practise on its own, the specific heat capacity guide owns it and the specific heat simulator puts it on its own screen, where the material and the mass are the controls instead of one half of a constant.
One gram of each, in Measure, on the default apparatus. The last two columns are the payload of the whole topic: the change in gaseous moles is read off the molecular formula before any arithmetic starts, and the gross-and-net cell says whether the water the burn made is inside the figure.
| Sample in the cup | Temperature rise card | Per gram card | Enthalpy card | Gas moles | Gross and net cell |
|---|---|---|---|---|---|
| Benzoic acid C7H6O2 | 2.6422 °C |
-26.422 kJ/g |
-3228.00 kJ/mol |
-0.5 |
26.43 gross; net not tabulated |
| Graphite C | 3.2762 °C |
-32.762 kJ/g |
-393.50 kJ/mol |
0 |
32.8 gross, 32.808 net; no water produced, so the difference is rounding |
| Ethanol C2H6O | 2.9619 °C |
-29.619 kJ/g |
-1367.00 kJ/mol |
-1 |
29.7 gross, 26.7 net; gap 10.10 per cent |
| Propan-1-ol C3H8O | 3.3551 °C |
-33.551 kJ/g |
-2020.00 kJ/mol |
-1.5 |
33.6 gross, 30.68 net; gap 8.69 per cent |
The graphite row is the cleanest demonstration this panel can give, and it needs no arithmetic at all. Carbon makes no water, so gross and net must coincide, and the tabulated pair reads 32.8 against 32.808. Carbon also gains no moles of gas, so the enthalpy and the internal energy are the same figure, and the card says so ΔH = ΔU exactly rather than quoting a tiny correction.
The band at the head of this page carries two relations, and every reading on the panel is a factor in one of them or a consequence of them. The rise is the only quantity the lab computes forwards from a tabulated energy density; everything below it is that rise being carried back out again.
The symbol column below uses the panel’s own names, and the “in this lab” column gives each slider’s real end stops with the readings measured at those positions. Six of the rows are not controls at all: they are computed, fixed, or one of four values set by a sample button.
| Symbol | What it is | SI unit | In this lab |
|---|---|---|---|
| ΔT | Temperature rise of the whole assembly. It is a difference, so degrees Celsius and kelvin are the same number here and nothing is added to convert | °C | the headline card, four significant figures. Across every combination of the three sliders and the four samples it runs from 0.3926 °C (benzoic acid, 0.20 g, 2500 g, 3.000) to 6.9168 °C (propan-1-ol, 1.50 g, 1500 g, 1.000), swept over the real grids rather than reasoned about. The all-minimum corner is not the floor: it reads 0.7263 °C. |
| Ccal | Calorimeter constant, also called the energy equivalent: the energy the whole assembly absorbs for each degree it warms | kJ/°C | a grid cell, and the quantity this lab exists to expose. It is never a slider: it is built from the two below it. The panel reaches 7.276 kJ/°C at the bottom of both apparatus sliders and 13.460 kJ/°C at the top of both, and sits at 10.000 kJ/°C on the opening setting. |
| mwater | Mass of water in the jacket. The first of the two things that absorb the heat | g | the second slider, 1500 to 2500 g in steps of 10, opening on 2000 g — the jacket volume the fetched apparatus description gives. It moves the water term from 6.276 to 10.460 kJ/°C and the rise from 3.3412 to 2.1851 °C for one gram of the calibrant. |
| Chardware | Heat capacity of the steel bomb, the stirrer and the thermometer. The second of the two, and the one most calculations on this topic drop | kJ/°C | the third slider, 1.000 to 3.000 in steps of 0.001, opening on 1.632, which corresponds to about 3.9 kg of stainless steel. It cannot be dragged to zero, so the water-only mistake is not reachable from this panel; its floor still leaves the constant at 9.368 kJ/°C. |
| cwater | Specific heat capacity of water, the number that turns a jacket mass into a heat capacity | J/(g·°C) | fixed at 4.184 and not exposed as a control. It is the thermochemical calorie by definition, and it is why 2000 g of water is exactly 8.368 kJ/°C. No slider on this panel changes it and no sample affects it. |
| m | Mass of sample weighed into the cup | g | the first slider, 0.20 to 1.50 g in steps of 0.01, opening on 1.00 g, which brackets the published practical range at both ends. It is the one control that moves the rise and the heat together while leaving the per-gram and per-mole cards exactly where they were. |
| qcal | Heat absorbed by the assembly. Positive, because the thermometer went up | kJ | the second card. Measured across the sliders from 5.284 kJ (0.20 g of the calibrant) to 50.327 kJ (1.50 g of propan-1-ol). It is always the sample’s energy density times its mass, never the constant times the displayed rise, because those two routes disagree in the last float on about a tenth of the reachable states. |
| qrxn | Heat of the reaction. The negative of the heat above, by energy conservation | kJ | the sub-line of the second card, and the first place the sign appears. For a combustion it is always negative and it is always printed with its minus sign; there is no setting of these controls that makes it positive. |
| ΔUg | Internal energy of combustion per gram. What a rigid vessel measures, because it does no pressure-volume work | kJ/g | the third card, and the quantity the apparatus cannot move. It takes exactly four values here, one per button: -26.422, -32.762, -29.619 and -33.551 kJ/g. The ladder beside the drawing plots the magnitude of this figure against published values. |
| n | Amount of sample burned, the mass divided by the molar mass | mol | a grid cell, six significant figures. From 0.00163769 mol (0.20 g of the calibrant) to 0.124886 mol (1.50 g of graphite, whose molar mass is the smallest of the four). It is the only quantity on the panel that depends on both the slider and the button. |
| M | Molar mass of whatever is in the cup | g/mol | a grid cell with exactly four values, because there are exactly four samples: 122.123, 12.011, 46.069 and 60.096 g/mol. None of them is a control, and the first is within 0.0014 per cent of the molar mass the fetched source states for benzoic acid. |
| ΔUm | Internal energy of combustion per mole: the per-gram figure multiplied by the molar mass | kJ/mol | the sub-line of the third card, two decimals. -3226.76, -393.50, -1364.52 and -2016.28 kJ/mol for the four samples. Only the button changes it; no slider on the panel does. |
| Δngas | Change in the number of moles of gas when the sample burns to carbon dioxide and liquid water. It may be negative, and it may be a half-integer | none — a count | a grid cell, read off the molecular formula rather than measured. -0.5, 0, -1 and -1.5 for the four samples. Zero is the interesting value, and it is the graphite column: no gas is gained or lost, so the last card has nothing to do. |
| ΔHm | Enthalpy of combustion per mole: the internal energy plus the pressure-volume term for the gases | kJ/mol | the fourth card. -3228.00, -393.50, -1367.00 and -2020.00 kJ/mol. The correction that separates it from the card above runs -1.2394, 0, -2.4788 and -3.7182 kJ/mol, and the card prints both the size and the sign of it every time. |
| HHV and LHV | Gross and net calorific values: with and without the energy released when the water the burn makes condenses | kJ/g | one wide grid cell, quoted as positive magnitudes and always labelled. 29.7 gross, 26.7 net; gap 10.10 per cent for ethanol; 33.6 gross, 30.68 net; gap 8.69 per cent for propan-1-ol; 32.8 gross, 32.808 net for graphite, where the difference is rounding. For benzoic acid the cell says net not tabulated rather than inventing one. |
The division by a thousand in the constant is the conversion most often dropped by hand. The specific heat capacity of water is quoted in joules and the whole panel works in kilojoules, so a jacket of 2000 g is 8.368 kJ/°C and not 8368. Getting it wrong by a factor of a thousand puts the rise somewhere no thermometer reads, which at least makes it visible.
Two symbols in that table collide with other pages on this site and are worth separating before you substitute. The capital letter used here for the calorimeter constant is a heat capacity in kilojoules per degree, not the capacitance of the same name, and the lower-case one is the specific heat capacity of a substance, not a speed. Both conventions are standard; neither page is wrong, and no reading here should be carried into a formula from the other.
The reason a bomb is made of thick steel is not safety alone. A rigid vessel cannot change volume, so the burning sample pushes nothing outwards and does no pressure-volume work — which means the energy it gives up is exactly the internal energy change, with no correction and no assumption. The first law of thermodynamics guide is where that step is set out properly, and the first law simulator is where the work term is a control you can take to zero yourself.
That one fact is why this apparatus measures what it measures. A reaction run in an open flask at atmospheric pressure does push the air back, and what you get there is an enthalpy change. The same reaction in the bomb gives an internal energy change instead, and the two differ by the work the gases would have done. On a pressure-volume plane a constant-volume path is a vertical line enclosing no area, which the pressure-volume diagram simulator draws directly.
The size of that difference is the last card on the panel, and the whole point is that it is decidable before you start. For a condensed fuel burning to carbon dioxide and liquid water, the change in gaseous moles depends on the hydrogen and oxygen counts alone and the carbon count cancels out, so you can read it off the formula. The grid prints it as -0.5, 0, -1 or -1.5 for the four samples, and the card turns it into a correction through the ideal gas relation.
And it is exactly zero whenever the hydrogen count is twice the oxygen count, which is the carbohydrate condition. A carbohydrate already carries its hydrogen and oxygen in the ratio they have in water, so burning it makes precisely as many moles of gas as it consumes. Graphite is the degenerate case of the same thing, which is why its two molar cards are the same number rather than two numbers that round alike.
The correction itself arrives through the relation between pressure, volume and amount for a gas — the ideal gas law guide is where that comes from — evaluated at 298.15 K with R = 8.314 J/(mol·K). That makes the whole term worth 2.4788 kJ for each mole of gas gained or lost, which is where the panel’s -1.2394, -2.4788 and -3.7182 kJ/mol come from.
Keep the size of it in proportion. For benzoic acid the correction is 0.0384 per cent of the internal energy figure, while the published uncertainty on the calibrant itself is 0.124 per cent — so the uncertainty on the standard substance is 3.23 times the size of the correction every textbook devotes a section to. That is not an argument for skipping the step. It is the measurement that tells you when the step can matter and when it cannot.
The second correction is physical rather than arithmetic. The vessel holds a little water of its own so that its atmosphere is saturated and everything the reaction makes ends up liquid, which means the energy given up as that water condenses is inside the reading. The answer is therefore a gross value, and the ladder on the right plots it against published gross values for the same reason.
| Part of the drawing | What it paints | What it does not claim |
|---|---|---|
| the apparatus, left panel | A cutaway titled with the sample and its mass — benzoic acid C7H6O2, 1.00 g — drawing seven labelled parts at a wide canvas: the water, the steel bomb, the cup, the dewar, the stirrer, the ignition leads and O2 at about 30 atm. The caption along its foot reads 2000 g of water, C_cal = 10.000 kJ/C |
none of it is to scale as an engineering drawing. The jacket level and the sample disc are driven by the two sliders so the picture cannot contradict the cards, but no dimension in the scene is a length you can measure off, and the number of labelled parts drops to four on a narrow canvas rather than overprinting |
| the thermometer | A stem covering a fixed span of 0 to 8 C above the start, with the starting reading at T_i, the finish at T_f and the rise bracketed between them. At a narrow canvas the readings move into the caption strip instead, as T_f 27.64 C, dT = 2.6422 C |
there is no elapsed time on this drawing and there never will be, because the approach to a steady reading belongs to a different topic. The span is fixed rather than fitted to the current rise, and every rise these sliders can reach sits inside it — an assertion in the reference suite, not an assumption |
| the ladder, right panel | A linear axis in kilojoules per gram from 0 to 60 with ticks every 10, carrying nine labelled published values at the width the figures on this page were captured at: benzoic acid 26.43, methane 55.52, pentane 48.64, propan-1-ol 33.6, ethanol 29.7, benzene 41.8, methanol 22.7, lignite coal 15.0 and damp peat 6.00. Its title degrades with the width, from energy density kJ/g, selected fetched values on the widest canvas to energy density, kJ/g on the figures below |
the axis is linear and the caption says so, because a logarithmic one over 6 to 142 would spend most of its length on empty space. The marker and the tick values share one scale, so the marker’s position against a named value is a real comparison rather than a decoration |
| hydrogen, and the shaded zone | Hydrogen is drawn above the top of the axis as an explicit arrow labelled H2 141.79, off scale, and the band above 55.52 is shaded and labelled impossible unless hydrogen, with the caption repeating above 55.52: impossible unless hydrogen |
nothing is silently omitted and nothing is compressed to make room. Putting hydrogen on the axis would squash the 15 to 50 region the whole topic lives in; dropping it would hide the real ceiling. The shading is drawn exactly when its claim is stated in words, never one without the other |
| what the marker can reach | A gold marker at the magnitude of the current per-gram figure. With these four buttons it only ever sits at 26.42, 32.76, 29.62 or 33.55 |
the higher bands are bounds to read against, not states these buttons can reach. All four samples sit in the lowest published band, at or below 33.6 kJ/g, so a reader who wants to see the marker in the hydrocarbon range has to take the figure to the calculator rather than expecting a button here to produce it |
-393.50 kJ/mol and the sub-line says Δngas = 0, so ΔH = ΔU exactly. The gross-and-net cell makes the other correction vanish too, at 32.8 gross, 32.808 net, because carbon makes no water for the vessel to condense.Every state the three sliders and six buttons reach is answered, and the arithmetic is not where this panel can let you down. What it cannot be is a standard-compliant determination, and what it refuses to do is treat its own idealisations as facts. The first two items below matter more than the rest together.
10.000 kJ/°C a property of bomb calorimeters in general. The table above puts eight different constants on the same gram of the same substance, from 7.908 to 12.092 kJ/°C, simply by moving two sliders. A constant has to be re-determined for the assembly in front of you, and that is the entire reason the Calibrate stage exists rather than being a number printed in a manual.2.6422 °C on a gram of the calibrant but applies 8.368 kJ/°C gets 22.110 kJ/g against a true 26.422, 16.3 per cent low and always low. This slider stops at 1.000, so the panel will not produce that state; the calculator will, if you type it.33.6, 48.64, 55.52 and 141.79 kJ/g — and the error above sails through it. So the band is a filter on the shape of an answer and not a proof of one. It is also worth knowing that all four samples here sit in the lowest band, at or below 33.6 kJ/g, so the higher bands are bounds the ladder draws rather than states these buttons can produce.net not tabulated where one is not, and the gap is the quantity the latent heat guide explains and the latent heat simulator draws.30.0 kJ/g, comfortably inside the band this lab would call plausible, which is precisely why a band check cannot substitute for a titration. None of the four samples here contains nitrogen or sulfur.1.00 g and 2.6422 °C give 10.000 kJ/°C. Burn half as much and it still gives 10.000 kJ/°C, from a rise of 1.3211 °C — which is the check that tells you the calibration is sound rather than a coincidence.2.9619 °C on a gram of ethanol becomes qcal = 29.619 kJ, then -29.619 kJ/g, then -1364.52 kJ/mol, then ΔH = -1367.00 kJ/mol. If you want that same chain with your own numbers in the boxes, the bomb calorimeter calculator is the page for it.0 for graphite and for every carbohydrate, so the step is exactly nothing and the two molar cards coincide. It is -1.5 for propan-1-ol, the largest here, and the correction is still only -3.7182 kJ/mol on a figure of -2016.28. Knowing which case you are in is more useful than doing the arithmetic twice.29.7 against 26.7 kJ/g for ethanol, a gap of 10.10 per cent. Anything to do with combustion efficiency, fuel comparison or energy content needs to know which it has. The quickest way to see what the gap is rather than how big it is, is to press Graphite and watch it disappear.6.00 to methane at 55.52 kJ/g, with hydrogen drawn off-scale at 141.79, and the marker sits at your own figure on the same axis. A figure above 55.52 is impossible for anything but hydrogen; a figure above 33.6 says the sample cannot be the oxygen-bearing kind. That is a filter worth applying, and the section above says plainly what it will not catch.3.3412 °C against 2.1851 °C for the same gram here — and both report -26.422 kJ/g. That is the property that makes the technique reproducible between laboratories at all, and it is visible on this panel in two clicks rather than being asserted in a paragraph.
2500 g of water instead of 2000. The water level in the drawing has risen, the constant has gone to 12.092 kJ/°C and the rise has fallen to 2.1851 °C — while the heat card still reads qcal = 26.422 kJ and the per-gram card still reads -26.422 kJ/g over -3226.76 kJ/mol. A different apparatus, a different reading, the same answer.A panel can put you in a state and let you move one thing at a time, and that is the end of what a panel is for. The bomb calorimeter equation guide is where the subject is written out: the four steps in order, the two corrections derived rather than quoted, and the problems worked from the thermometer reading to the molar answer.
Four posts own the pieces this lab takes as read. The first law of thermodynamics guide is where a rigid vessel doing no work comes from, the laws of thermodynamics guide puts that law in context, the ideal gas law guide owns the relation behind the gas-moles correction, and the pressure-volume diagram guide is where a constant-volume path enclosing no area is the subject.
Four more are worth having beside this one. The specific heat capacity guide and the specific heat capacity of water guide own the jacket term and the figure inside it, the latent heat guide owns the gross-and-net gap, and the difference between heat and temperature is the distinction the whole first card depends on. The energy conversion examples guide is where combustion sits among the rest.
On the tool side, the bomb calorimeter calculator takes typed figures and rearranges this chain in five directions, the reaction enthalpy calculator runs the step after it, the specific heat calculator does the jacket term on its own, the first law calculator does the law underneath all of it, and the water heating calculator is the quickest check on a jacket figure.
Four neighbouring pictures sit beside this one: the specific heat simulator, the latent heat simulator, the first law of thermodynamics simulator and the pressure-volume diagram simulator. Beyond them there is the simulation library, an index of calculators, and the blog for everything written out at length.
Because the rise measures the burn and the per-gram figure measures the substance. Take benzoic acid from 1.00 g to 0.50 g and the rise card goes from 2.6422 to 1.3211 degrees Celsius and the heat card from 26.422 to 13.211 kJ, while the per-gram card holds at -26.422 kJ/g and the per-mole line at -3226.76 kJ/mol. That invariance is exactly what makes calibration worth doing.
It is the energy the whole assembly absorbs per degree, and it comes in two parts that no other free tool separates. The grid shows both: at the opening setting it reads 10.000 kJ per degree Celsius, of which 8.368 is the water jacket and 1.632 is the steel, the stirrer and the thermometer. Move either slider and the constant moves with it.
Because they are two different quantities with two different conventions. The card reports an energy change for the reaction, which loses energy, so it is negative and the sign is the physics rather than a formatting choice. The ladder plots a calorific value, which is conventionally quoted as a positive magnitude, and the grid labels it gross or net so the two cannot be confused.
Because burning carbon consumes exactly as many moles of gas as it makes, so the correction term is exactly zero rather than merely small. The sub-line reads that the change in gaseous moles is 0 and the two cards are identical at -393.50 kJ/mol. It is decidable from the formula before any arithmetic starts, and the same is true of every carbohydrate.
Gross, because the bomb condenses the water its own reaction makes, so the energy given up on condensing is inside what the thermometer reads. Press Ethanol and the cell reads 29.7 gross, 26.7 net, with a gap of 10.10 per cent. Press Graphite and it reads 32.8 gross against 32.808 net, because carbon makes no water and the difference is rounding.
0.3926 degrees Celsius and 6.9168 degrees Celsius. The floor is 0.20 g of benzoic acid in 2500 g of water with the hardware at 3.000, and the ceiling is 1.50 g of propan-1-ol in 1500 g of water with the hardware at 1.000. Both were found by sweeping the real slider grids rather than by reasoning about corners, which matters because the smallest sample does not sit at the smallest rise.
Because a calibration run on graphite is not a calibration. Calibrate works by assuming the energy density of what is in the cup is already known, which is true of the standard calibrant and of nothing else here, so the stage forces benzoic acid into the cup. Choosing another sample is therefore a statement that you are measuring rather than calibrating, and the panel follows you.
No, and one measured case shows why. The band checks a per-gram figure against four published bounds at 33.6, 48.64, 55.52 and 141.79 kJ/g, so it catches the impossible. A reader who measures the rise correctly but uses the water term alone as the constant gets 22.110 kJ/g against a true 26.422, which is 16.3 per cent low and still inside a plausible band.
Any picture of the reading climbing to its final value. The approach to a steady temperature is a separate topic with its own formula and its own page, so this panel draws the thermometer with the start and finish marked and the bracket between them, and no elapsed seconds anywhere. It also has four samples and no box to type an unknown one into.