{"id":2452,"date":"2026-11-19T01:33:17","date_gmt":"2026-11-19T01:33:17","guid":{"rendered":"https:\/\/physicsfundamentalsinfo.com\/blog\/?p=2452"},"modified":"2026-11-19T01:33:20","modified_gmt":"2026-11-19T01:33:20","slug":"heat-flux","status":"publish","type":"post","link":"https:\/\/physicsfundamentalsinfo.com\/blog\/thermodynamics\/heat-flux\/","title":{"rendered":"Heat Flux Units: W\/m2, the Formula and Why Area Matters"},"content":{"rendered":"\n<div class=\"pf-citation\"><div class=\"eyebrow\">Definition<\/div><p>\n\nHeat flux units are watts per square metre, W\/m\u00b2, because a heat flux is a power spread over an area. The flux q is the heat energy Q divided by the area A it crossed and the time t it took, so one watt per square metre means one joule per second through every square metre of surface.\n\n<\/p><\/div>\n\n<p>Put your hand flat on an outside wall in January. Slide it along to a wider stretch of the same brick and nothing changes \u2014 the wall does not feel colder for being bigger. Yet that bigger stretch is undeniably losing more heat in total. Both of those things are true at the same time, and the only way to hold them both is to stop using one number for two different quantities.<\/p>\n\n<p>That is what this page is about. A heat flux is the figure that stays put when a surface grows; a heat transfer rate is the figure that grows with it. Heat flux units are what keep the two apart on paper, and mixing them up is the quietest way a thermal calculation goes wrong.<\/p>\n\n<h2>What Is Heat Flux?<\/h2>\n\n<p>Heat flux is the rate at which heat energy crosses a surface, counted per square metre of that surface. It is a power per unit area, not a power, and the symbol for it on this page is a lowercase q.<\/p>\n\n<p>Think of it as a measure of how hard a surface is working rather than how much work it does. Two walls can be shifting very different amounts of energy per second and still be under identical thermal pressure, because one of them simply has more square metres to do it through. The flux is what survives that comparison.<\/p>\n\n<p>Heat is energy in transit, which is why the quantity on top of the formula is an energy and not a temperature \u2014 a distinction our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/thermodynamics\/heat-vs-temperature\/\">heat against temperature<\/a> settles properly. A flux tells you how fast that transit is happening across a given face, and nothing at all about how hot either side of it is.<\/p>\n\n<h2>The Unit of Heat Flux: Watts per Square Metre<\/h2>\n\n<p>The SI unit of heat flux is the watt per square metre, written W\/m<sup>2<\/sup>. Nothing else is the SI unit, though seven other units are in daily use and the whole of the conversion table further down exists for them.<\/p>\n\n<p>Unpack it and the unit explains itself. A watt is a joule per second, so a watt per square metre is a joule per second through each square metre: W\/m<sup>2<\/sup> = J\/(s\u00b7m<sup>2<\/sup>). Push it down to SI base units and it collapses to kg\/s<sup>3<\/sup>, with the metres cancelling out entirely \u2014 a result that looks wrong until you notice it is just a watt, which already carries m<sup>2<\/sup>, divided by m<sup>2<\/sup> again. Our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/mechanics\/si-units-physics\/\">SI units in physics<\/a> sets out where derived units like this come from.<\/p>\n\n<p>The quantity travels under several names, and it is worth recognising all of them. The standard reference on <a href=\"https:\/\/en.wikipedia.org\/wiki\/Heat_flux\" target=\"_blank\" rel=\"noopener\">heat flux<\/a> gives heat flux density, heat-flow density and heat-flow rate intensity as alternative names for the same thing \u2014 a flow of energy per unit area per unit time \u2014 and records its SI units as watts per square metre. None of those names describes a different quantity. If a paper hands you a heat flux density in W\/m<sup>2<\/sup>, it has handed you a heat flux.<\/p>\n\n<p>One further property, stated once because it matters and then left alone. A heat flux has a direction as well as a magnitude, since energy crosses a surface one way rather than the other, which makes it formally a <strong>vector quantity<\/strong>. Everything on this page is its magnitude through one surface; the sign convention and the surface integral are a separate subject.<\/p>\n\n<h2>The Heat Flux Formula<\/h2>\n\n<p>The heat flux formula is q = Q \/ (A t): the heat energy that crossed, divided by the area it crossed and the time it took. The same relation reads as the heat transfer rate divided by the area, which is often the quicker route.<\/p>\n\n<div class=\"pf-formula\">q = Q \/ (A t)&nbsp;&nbsp;&nbsp;&nbsp;Q\/t = Q \/ t&nbsp;&nbsp;&nbsp;&nbsp;q = (Q\/t) \/ A<\/div>\n\n<p>Every symbol, with the unit it has to be in before anything is divided by anything:<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Symbol<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">What it is<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">SI unit<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Value in this page&#8217;s figures<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">q<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">Heat flux: the power crossing one square metre of the surface. Lowercase, always<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">watt per square metre, W\/m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">250 W\/m<sup>2<\/sup> in the worked anchor; 90 W\/m<sup>2<\/sup> for the brick wall<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">Q<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">The heat energy that crossed. Uppercase, and a total rather than a per-square-metre figure<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">joule, J<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1800000 J, which is 1.8 MJ<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">A<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">The area the heat crossed, measured across the flow rather than along it. Strictly positive<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">square metre, m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">2 m<sup>2<\/sup> in the anchor; 1 m<sup>2<\/sup> and 12 m<sup>2<\/sup> in Figure 1<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">t<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">The time over which that energy crossed. Strictly positive<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">second, s<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">3600 s, which is one hour<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">Q\/t<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">Heat transfer rate through the whole surface: the flux multiplied by the area. A different quantity, in a different unit<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">watt, W<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">500 W in the anchor; 90 W and 1080 W in Figure 1<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Settle the letters now rather than being ambushed later, because physics is not consistent about them and nor is this site. Here lowercase q is the <em>flux<\/em> and uppercase Q is the <em>energy<\/em>, which is the convention our <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/specific-heat\">specific heat calculator<\/a> keeps; our <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/water-heating\">water heating calculator<\/a>, though, uses a lowercase q for the heat energy itself, in joules, and so does the reaction-enthalpy one. Check which quantity a copied figure is, not just which unit it is in.<\/p>\n\n<p>Three of the four quantities are yours to supply and the fourth drops out, so the line rearranges four ways: Q = q A t, A = Q \/ (q t) and t = Q \/ (q A). The <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/heat-flux\">Heat Flux Calculator<\/a> runs any of those four directions and prints the answer in all eight flux units at once, which is the fastest way through a question that arrives in kWh and wants an answer in BTU. The energy on top is usually the thing that was actually measured, and our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/thermodynamics\/specific-heat-capacity\/\">specific heat capacity<\/a> is where that Q comes from if you have to work it out first.<\/p>\n\n<p>One limit, stated once, because it is the honest boundary of the formula. Dividing by A assumes the flux is the same everywhere over that area, and dividing by t assumes it held steady for the whole period. What q = Q \/ (A t) returns is therefore an <strong>average<\/strong> over both \u2014 which is exactly right for a uniform surface and merely a reasonable summary for a patchy one.<\/p>\n\n<p>The simulator below is the quickest way to feel what the formula does and does not depend on. Drag the <strong>area<\/strong> slider and watch the first readout card, <code>Heat flux q (W\/m\u00b2)<\/code>, sit perfectly still while the watts move with it; then click through the five material buttons, <code>Aerogel 0.015<\/code>, <code>Wool 0.040<\/code>, <code>Wood 0.13<\/code>, <code>Brick 0.72<\/code> and <code>Copper 401<\/code>, and watch the flux span four orders of magnitude without the area changing at all.<\/p>\n\n<div class=\"pf-sim-slot\"><div class=\"pf-sim-slot-header\"><span class=\"icon-dot\"><\/span><span class=\"label\">Fourier&#039;s Law Lab<\/span><\/div><div class=\"pf-sim-slot-body\"><style>.pf-sim-frame{width:100%;border:none;height:600px}@media(max-width:760px){.pf-sim-frame{height:1000px}}<\/style><iframe src=\"\/labs\/fouriers-law.html?embed=1\" class=\"pf-sim-frame\" loading=\"lazy\"><\/iframe><\/div><\/div>\n\n<h2>Heat Flux vs Heat Transfer Rate<\/h2>\n\n<p>A heat transfer rate is the power crossing a whole surface, measured in watts; a heat flux is that power per square metre of the surface, measured in W\/m<sup>2<\/sup>. One is a total, the other is a density, and the area is what converts between them.<\/p>\n\n<p>For a wall the flux can be written straight from the material rather than from a measured energy. That relation is Fourier&#8217;s law in flux form, and it belongs to our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/thermodynamics\/fouriers-law\/\">Fourier&#8217;s law of heat conduction<\/a>, which derives it and carries the conductivity table; it is stated here once, for the one purpose of pinning a flux down while the area changes, and not developed.<\/p>\n\n<div class=\"pf-formula\">q = k \u0394T \/ d&nbsp;&nbsp;&nbsp;&nbsp;Q\/t = q A<\/div>\n\n<p>Look at what is missing from that first line. There is no A in it \u2014 just the conductivity k, the temperature difference \u0394T and the thickness d. So for a given material at a given temperature difference and thickness, the flux is fixed before anyone has said how big the wall is.<\/p>\n\n<p>Take brick, k = 0.72 W\/(m\u00b7K), with \u0394T = 20 K across d = 0.160 m. The flux is 90 W\/m<sup>2<\/sup>, and it is 90 W\/m<sup>2<\/sup> for a stamp-sized patch and for the gable end of a house. The <em>rate<\/em> is what tells them apart: 90 W through one square metre, 1080 W through twelve of them.<\/p>\n\n<figure style=\"margin:32px auto;max-width:720px;text-align:center;\">\n  <img src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/11\/heat-flux-diagram-01-768x427.jpg\" srcset=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/11\/heat-flux-diagram-01-768x427.jpg 768w, https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/11\/heat-flux-diagram-01.jpg 1520w\" sizes=\"auto, (max-width: 760px) 100vw, 720px\" width=\"1520\" height=\"846\" alt=\"Figure 1. One brick wall drawn twice at one shared scale, with a temperature difference of 20 kelvin across a thickness of 0.160 metres. On the left a single dark square tile represents an area of 1 square metre, with one arrow entering it from the left labelled heat. Beneath it two labels read rate Q over t equals 90 watts and flux q equals 90 watts per square metre. On the right, twelve identical tiles of exactly the same size are arranged in four columns and three rows, representing an area of 12 square metres, with three arrows entering from the left. Beneath that grid two labels read rate Q over t equals 1080 watts and flux q equals 90 watts per square metre. Three closing lines of text state that twelve times the area gives twelve times the rate, 90 watts becoming 1080 watts, that each tile still passes 90 watts per square metre so the flux does not change when the area does, and that with a conductivity of 0.72 watts per metre kelvin the flux q equals k times dT over d equals 0.72 times 125 equals 90 watts per square metre. A final line notes that the figures are stated givens taken from the simulator preset and are not a measurement of any real wall. The arrows on both sides enter at the wall's left face and mark the heat going in; they are not a count of one arrow per tile.\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:4px;\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Figure 1. One brick wall at \u0394T = 20 K across d = 0.160 m, drawn twice on one shared scale: a single square metre on the left, twelve of those same square metres on the right. Every tile passes 90 W\/m\u00b2, so the flux does not change when the area does; the rate through the whole surface is 90 W on the left and 1080 W on the right. The arrows mark the heat entering each wall&#8217;s left face and are not a count of one arrow per tile.<\/figcaption>\n<\/figure>\n\n<p>Now the detail that makes the two genuinely confusable rather than merely different. At an area of exactly 1 m<sup>2<\/sup> the rate in watts and the flux in W\/m<sup>2<\/sup> come out as the <em>same number<\/em> \u2014 90 and 90 \u2014 while meaning different things. Move off one square metre and they part company immediately, which is why a flux and a rate quoted as the same figure should always make you check the area.<\/p>\n\n<h2>Why the Area Cancels<\/h2>\n\n<p>The area cancels because the flux is already a per-square-metre quantity: multiplying it by the area gives the rate, and dividing that rate by the area gives it straight back. Nothing about the material or the temperature difference changed in between.<\/p>\n\n<p>The simulator above makes this a two-second experiment. Its area slider runs from 0.1 to 20 m<sup>2<\/sup>, and at its boot settings \u2014 conductivity 0.040, a temperature difference of 20 K, a thickness of 0.160 m \u2014 dragging it does this:<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Area A (m<sup>2<\/sup>)<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Heat flux q (W\/m<sup>2<\/sup>)<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Heat transfer rate Q\/t (W)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.1<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.5<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">2<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">10<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">25<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">10<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">50<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">20<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">5<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">100<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Two hundred times the area. The flux does not change, and the rate goes up by the same factor of 200. Two of its other readout cards, <code>Resistance R (m\u00b2\u00b7K\/W)<\/code> and <code>U-value (W\/m\u00b2\u00b7K)<\/code>, read 4 and 0.25 at those boot settings, each printed to three decimal places, and stay there for the same reason the flux does: both are per-unit-area quantities, and both belong to the heat-loss topic rather than to this one.<\/p>\n\n<p>Here is the catch that trips people who have just read the formula, though. Look at q = Q \/ (A t) again: there <em>is<\/em> an A on the bottom, so how can the flux not depend on it? Because the two experiments hold different things fixed.<\/p>\n\n<ul>\n<li><strong>Fix the material, the temperature difference and the thickness<\/strong> \u2014 what the simulator&#8217;s sliders do \u2014 and the flux is pinned at k \u0394T \/ d while the rate rises in proportion to the area. That is the table above.<\/li>\n<li><strong>Fix the energy and the time instead<\/strong> \u2014 what q = Q \/ (A t) does, and what the calculator&#8217;s presets do \u2014 and the <em>rate<\/em> is pinned while the flux falls as 1\/A. At Q = 1.8 MJ in one hour, the rate is 500 W whatever the area, and the flux reads 500 W\/m<sup>2<\/sup> at 1 m<sup>2<\/sup>, 250 W\/m<sup>2<\/sup> at 2 m<sup>2<\/sup> and 25 W\/m<sup>2<\/sup> at 20 m<sup>2<\/sup>.<\/li>\n<\/ul>\n\n<p>Both statements are correct and they are not in conflict, because they are answers to different questions. Spreading a fixed amount of energy over more surface really does thin the flux out; giving a wall more area at the same driving conditions really does not. Say which quantities you are holding still and the apparent paradox evaporates.<\/p>\n\n<h2>Converting Heat Flux Units<\/h2>\n\n<p>Every heat flux unit in common use converts to W\/m<sup>2<\/sup> by a single multiplication, and all eight factors come from defined-exact values rather than from measurements. The table below is the whole ladder, with the 250 W\/m<sup>2<\/sup> anchor from the worked problems carried across it.<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Unit<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">One of these in W\/m<sup>2<\/sup><\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">Where the factor comes from<\/th>\n<th style=\"padding:9px 10px;text-align:left;border:1px solid #D9CFB8;\">250 W\/m<sup>2<\/sup> reads as<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">W\/m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">the SI unit, by definition<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">250<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">kW\/m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1000<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">the SI prefix kilo<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.25<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">MW\/m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1000000<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">the SI prefix mega<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.00025<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">W\/cm<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">10000<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1 cm = 0.01 m, so 1 cm<sup>2<\/sup> = 0.0001 m<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.025<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">mW\/cm<sup>2<\/sup><\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">10<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">the same cm<sup>2<\/sup>, with milli on the watt<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">25<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">cal\/(s\u00b7cm<sup>2<\/sup>)<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">41840<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1 thermochemical calorie = 4.184 J exactly<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">0.00597514<\/td><\/tr>\n<tr><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">kcal\/(h\u00b7m<sup>2<\/sup>)<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1.162222<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">4184 J over 3600 s, an exact ratio<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">215.105<\/td><\/tr>\n<tr style=\"background:#F5F2EA;\"><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">BTU\/(h\u00b7ft<sup>2<\/sup>)<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">3.154591<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">1055.05585262 J over 334.450944 s\u00b7m<sup>2<\/sup>, an exact ratio<\/td><td style=\"padding:9px 10px;border:1px solid #D9CFB8;\">79.2496<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Going the other way, the two reciprocals worth memorising are 1 W\/m<sup>2<\/sup> = 0.316998 BTU\/(h\u00b7ft<sup>2<\/sup>) and 1 W\/m<sup>2<\/sup> = 0.860421 kcal\/(h\u00b7m<sup>2<\/sup>). Note that neither of those, nor the BTU factor itself, is anywhere near a power of ten. Shifting a decimal point will convert W\/m<sup>2<\/sup> to kW\/m<sup>2<\/sup> and stop working the moment a foot or a calorie appears \u2014 the general method is in our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/mechanics\/physics-unit-conversions\/\">physics unit conversions<\/a>.<\/p>\n\n<h2>Common Misconceptions About Heat Flux<\/h2>\n\n<p>Four beliefs cause most of the wrong answers, and the first is the one the unit itself invites.<\/p>\n\n<h3>&#8220;W\/m<sup>2<\/sup> is just a fussy way of writing watts&#8221;<\/h3>\n\n<p>It is not: the two are different quantities and cannot be substituted for each other. The belief survives because they agree numerically at exactly 1 m<sup>2<\/sup> \u2014 our brick wall gave 90 W and 90 W\/m<sup>2<\/sup> there \u2014 and because a lot of worked examples quietly use a one-square-metre sample. Enter any other area and the two figures separate.<\/p>\n\n<h3>&#8220;A bigger wall has a bigger heat flux&#8221;<\/h3>\n\n<p>A bigger wall loses more heat per second, which is a bigger <em>rate<\/em>, and that is almost certainly what the sentence was reaching for. At the same material, temperature difference and thickness the flux is identical: that is the whole content of the table two sections up, where the area moved by a factor of 200 and the flux did not change at all.<\/p>\n\n<h3>&#8220;One flux figure describes the whole surface&#8221;<\/h3>\n\n<p>It describes the average, and a real surface is rarely uniform. Dividing by A buries every cold bridge, every stud and every poorly-fitted panel inside a single number, and a thermal camera shows the difference instantly. The average is still the right quantity for an energy sum; it is simply not the peak.<\/p>\n\n<figure style=\"margin:32px auto;max-width:640px;text-align:center;\">\n  <img decoding=\"async\" src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/11\/a-thermal-camera-image-of-a-house-wall-in-winter.avif\"\n       alt=\"Thermal camera image of a house wall in winter, with brighter false-colour patches marking the parts of the wall with the highest heat flux in watts per square metre, the heat flux units used throughout this page.\"\n       loading=\"lazy\"\n       style=\"width:100%;height:auto;border-radius:4px;\" \/>\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Thermography makes a heat flux visible. The brighter the false colour, the harder that part of the wall is working, and the clearer it is that one average figure cannot describe the whole surface.<\/figcaption>\n<\/figure>\n\n<h3>&#8220;Flux units convert by moving the decimal point&#8221;<\/h3>\n\n<p>Only within the SI prefixes. The factor for BTU\/(h\u00b7ft<sup>2<\/sup>) is 3.154591, the factor for kcal\/(h\u00b7m<sup>2<\/sup>) is 1.162222, and both are exact ratios that happen to look like untidy decimals. Round the BTU factor to &#8220;about 3&#8221; and every answer comes out roughly five per cent low; round the kcal one to &#8220;about 1&#8221; and it is low by about fourteen per cent, before any physics has been attempted.<\/p>\n\n<h2>Where Heat Flux Fits Among the Thermal Quantities<\/h2>\n\n<p>Heat flux is the per-area measure of heat <em>moving<\/em>, which places it next to three families of quantity rather than inside any of them.<\/p>\n\n<p>First, the transport mode. A flux can be carried by conduction, by convection or by radiation, and our guide to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/thermodynamics\/conduction-convection-radiation\/\">conduction, convection and radiation<\/a> is the place to settle &#8220;a flux of what, exactly?&#8221;; the <a href=\"https:\/\/physicsfundamentalsinfo.com\/labs\/heat-transfer-simulator\">heat transfer simulator<\/a> shows all three shifting energy side by side.<\/p>\n\n<p>Second, the material route. When the driving conditions are what you know rather than a measured energy, the <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/thermal-conduction\">thermal conduction calculator<\/a> is the tool \u2014 but it asks for an <em>area<\/em> alongside the conductivity, the temperature difference and the thickness, and what it hands back is the whole-surface rate in watts rather than a flux, so divide those watts by the area you typed to get back to W\/m<sup>2<\/sup>. The <a href=\"https:\/\/physicsfundamentalsinfo.com\/labs\/fouriers-law-simulator\">Fourier&#8217;s law simulator<\/a> is the landing page of the sim embedded above, if you want it on its own.<\/p>\n\n<p>Third, the question a flux cannot answer: how quickly a temperature change travels rather than how much energy crosses. That is thermal diffusivity, in m<sup>2<\/sup>\/s, and the <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/thermal-diffusivity\">thermal diffusivity calculator<\/a> handles it. A high flux and a slow response are perfectly compatible, which catches people out more often than it should.<\/p>\n\n<h2>Worked Problems<\/h2>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 1<\/div><div class=\"pf-problem-question\">1.8 MJ of heat crosses a surface of area 2 m\u00b2 in one hour. Find the heat flux in W\/m\u00b2 and the heat transfer rate in W.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Use q = Q \/ (A t), and put both inputs into SI first: Q = 1.8 MJ = 1800000 J, and t = 1 h = 3600 s.\n\nStep 2: Form the product underneath the line, which is the step most often skipped: A t = 2 \u00d7 3600 = 7200 m<sup>2<\/sup>\u00b7s.\n\nStep 3: q = 1800000 \/ 7200 = 250 W\/m<sup>2<\/sup>. Then the rate, by the other route: Q\/t = 1800000 \/ 3600 = 500 W, and 500 \/ 2 = 250 W\/m<sup>2<\/sup> again.\n\n<strong>Answer: q = 250 W\/m<sup>2<\/sup> and the heat transfer rate is 500 W. Both are exact; the two routes to the flux agree because dividing by A t and dividing by t then by A are the same operation.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 2<\/div><div class=\"pf-problem-question\">A surface passes 1.8 MJ in one hour at a heat flux of 250 W\/m\u00b2. How large is it?<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Rearrange for the area: A = Q \/ (q t).\n\nStep 2: Form the denominator: q t = 250 \u00d7 3600 = 900000 J\/m<sup>2<\/sup>. That is the energy one square metre of the surface passed in the hour.\n\nStep 3: A = 1800000 \/ 900000 = 2 m<sup>2<\/sup>.\n\n<strong>Answer: A = 2 m<sup>2<\/sup>, exactly the area problem 1 started from. A flux of zero has no answer in this direction at all \u2014 it would need an infinite area to pass a real amount of energy.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 3<\/div><div class=\"pf-problem-question\">One kilowatt hour of heat crosses 4 m\u00b2 of surface over two hours. Find the heat flux and the rate.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Convert the energy. One kilowatt hour is 1000 W for 3600 s, so Q = 1000 \u00d7 3600 = 3600000 J, and t = 2 h = 7200 s.\n\nStep 2: A t = 4 \u00d7 7200 = 28800 m<sup>2<\/sup>\u00b7s.\n\nStep 3: q = 3600000 \/ 28800 = 125 W\/m<sup>2<\/sup>. The rate is Q\/t = 3600000 \/ 7200 = 500 W, and 500 \/ 4 = 125 W\/m<sup>2<\/sup> as a check.\n\n<strong>Answer: q = 125 W\/m<sup>2<\/sup> at a rate of 500 W. Note that the rate is the same 500 W as problem 1 even though the energy and the time are both different \u2014 the flux is half, because the area is double.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 4<\/div><div class=\"pf-problem-question\">Express 250 W\/m\u00b2 in W\/cm\u00b2 and then in BTU\/(h\u00b7ft\u00b2), showing where each factor comes from.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: One square centimetre is 0.0001 m<sup>2<\/sup>, so 1 W\/cm<sup>2<\/sup> = 10000 W\/m<sup>2<\/sup>. Divide: 250 \/ 10000 = 0.025 W\/cm<sup>2<\/sup>.\n\nStep 2: Build the BTU factor rather than looking it up. 1 ft = 0.3048 m exactly, so 1 ft<sup>2<\/sup> = 0.3048 \u00d7 0.3048 = 0.09290304 m<sup>2<\/sup>, and one hour-square-foot is 3600 \u00d7 0.09290304 = 334.450944 s\u00b7m<sup>2<\/sup>. One International Table BTU is exactly 1055.05585262 J, so 1 BTU\/(h\u00b7ft<sup>2<\/sup>) = 1055.05585262 \/ 334.450944 = 3.154591 W\/m<sup>2<\/sup>.\n\nStep 3: Divide by that factor: 250 \/ 3.154591 = 79.2496 BTU\/(h\u00b7ft<sup>2<\/sup>) to six significant figures.\n\n<strong>Answer: 250 W\/m<sup>2<\/sup> = 0.025 W\/cm<sup>2<\/sup> = 79.2496 BTU\/(h\u00b7ft<sup>2<\/sup>). One flux, three ways of writing it; not one of the three factors is a measurement.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 5<\/div><div class=\"pf-problem-question\">A heat flux arrives written as 79.2496 BTU\/(h\u00b7ft\u00b2). Convert it into SI, by two independent routes.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Going into SI you multiply by the same factor you divided by before: 1 BTU\/(h\u00b7ft<sup>2<\/sup>) = 3.154591 W\/m<sup>2<\/sup>.\n\nStep 2: 79.2496 \u00d7 3.154591 = 250.000 W\/m<sup>2<\/sup> to six significant figures.\n\nStep 3: Check it the other way, with the reciprocal. 1 W\/m<sup>2<\/sup> = 0.316998 BTU\/(h\u00b7ft<sup>2<\/sup>), so 79.2496 \/ 0.316998 = 250.000 W\/m<sup>2<\/sup>. The two routes agree.\n\n<strong>Answer: 250 W\/m<sup>2<\/sup>, which is problem 1&#8217;s flux back again. The trailing figures differ in the last digit or two depending on how far the factor was rounded, which is why the factor is worth keeping to seven figures rather than three.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 6<\/div><div class=\"pf-problem-question\">A brick wall has a conductivity of 0.72 W\/(m\u00b7K) and a thickness of 0.160 m, with a temperature difference of 20 K across it. Find the heat flux and the heat transfer rate for a 1 m\u00b2 patch and for a 12 m\u00b2 wall of the same brick.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Here the driving conditions are known rather than an energy, so take the flux from the material route, q = k \u0394T \/ d. There is no area in it.\n\nStep 2: \u0394T \/ d = 20 \/ 0.160 = 125 K\/m, so q = 0.72 \u00d7 125 = 90 W\/m<sup>2<\/sup>. That is the flux for both walls, because the area never enters.\n\nStep 3: The rate is the flux times the area, Q\/t = q A. Small patch: 90 \u00d7 1 = 90 W. Large wall: 90 \u00d7 12 = 1080 W, and 1080 \/ 90 = 12, exactly the area ratio.\n\n<strong>Answer: both walls carry 90 W\/m<sup>2<\/sup>; the rates are 90 W and 1080 W. Watch the first case: at exactly 1 m<sup>2<\/sup> the rate in watts and the flux in W\/m<sup>2<\/sup> are the same number, 90, while being different quantities in different units.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 7<\/div><div class=\"pf-problem-question\">The simulator above boots with a conductivity of 0.040 W\/(m\u00b7K), a temperature difference of 20 K, a thickness of 0.160 m and an area of 10 m\u00b2. Work out its heat flux and heat transfer rate by hand, then check them on screen.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Same material route, and again the area stays out of the flux: q = k \u0394T \/ d.\n\nStep 2: The geometry is unchanged from problem 6, so \u0394T \/ d = 20 \/ 0.160 = 125 K\/m, and q = 0.040 \u00d7 125 = 5 W\/m<sup>2<\/sup>.\n\nStep 3: The rate follows from the area: Q\/t = q A = 5 \u00d7 10 = 50 W.\n\n<strong>Answer: q = 5 W\/m<sup>2<\/sup> and the rate is 50 W. Scroll up and confirm it: the card reading <code>Heat flux q (W\/m\u00b2)<\/code> shows 5 to three decimal places, and the rate above it shows 50 W to one. Then drag the area slider across its whole range, 0.1 to 20 m<sup>2<\/sup>: the flux does not change, while the rate runs from 0.5 W to 100 W.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 8<\/div><div class=\"pf-problem-question\">Keeping that same geometry and temperature difference, the simulator&#039;s material buttons change only the conductivity. Compare the heat flux for Wool 0.040 with the heat flux for Copper 401.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: The geometry fixes the same bracket for both materials: \u0394T \/ d = 20 \/ 0.160 = 125 K\/m.\n\nStep 2: Wool: q = 0.040 \u00d7 125 = 5 W\/m<sup>2<\/sup>. Copper: q = 401 \u00d7 125 = 50125 W\/m<sup>2<\/sup>.\n\nStep 3: The ratio of the two fluxes is 50125 \/ 5 = 10025.\n\n<strong>Answer: 5 W\/m<sup>2<\/sup> against 50125 W\/m<sup>2<\/sup> \u2014 a factor of 10025 from the conductivity alone. The area appeared in neither calculation, and that is precisely why a flux is the fair way to compare two materials: resize both walls and both figures stay exactly where they are.<\/strong>\n\n<\/div><\/details><\/div>\n\n<h2>Frequently Asked Questions<\/h2>\n\n<details class=\"pf-faq-item\"><summary>What is the unit of heat flux?<\/summary><div class=\"pf-faq-item-answer\">\n\nThe SI unit of heat flux is the watt per square metre, W\/m\u00b2. It is a power per unit area, so it is equally J\/(s\u00b7m<sup>2<\/sup>), and in SI base units it reduces to kg\/s<sup>3<\/sup>. Seven other units are in regular use, including kW\/m\u00b2, W\/cm\u00b2, cal\/(s\u00b7cm\u00b2), kcal\/(h\u00b7m\u00b2) and BTU\/(h\u00b7ft\u00b2), and every one of them converts to W\/m\u00b2 by an exactly defined factor.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Is heat flux the same as the heat transfer rate?<\/summary><div class=\"pf-faq-item-answer\">\n\nNo. The rate is the power crossing a whole surface, in watts; the flux is the power per square metre of it, in W\/m\u00b2. The area converts between them, since the rate equals the flux times the area. They are easy to confuse because at exactly one square metre the two come out as the same number, which is a coincidence of the area rather than a statement about the physics.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>If heat flux does not depend on area, why is area in the formula?<\/summary><div class=\"pf-faq-item-answer\">\n\nBecause what the flux depends on is whatever you are holding fixed. Divide a fixed amount of energy by a bigger area and the flux really does fall, which is what q = Q \/ (A t) describes. Fix the material, the temperature difference and the thickness instead, and the flux is already determined before any area is named, so enlarging the surface raises only the rate.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>How do you convert W\/m\u00b2 into BTU per hour per square foot?<\/summary><div class=\"pf-faq-item-answer\">\n\nDivide by 3.154591, or multiply by 0.316998 for the same result. That factor is not measured: one International Table BTU is exactly 1055.05585262 J and one foot is exactly 0.3048 m, so one square foot is exactly 0.09290304 m\u00b2. A flux of 250 W\/m\u00b2 is therefore 79.2496 BTU\/(h\u00b7ft\u00b2), and rounding the factor to 3 costs several per cent.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What is a typical heat flux?<\/summary><div class=\"pf-faq-item-answer\">\n\nThis page quotes no typical value on purpose, because no measured flux was sourced for it and a remembered figure would be a guess. A flux depends on the material, the temperature difference and the geometry, and the same surface can carry fluxes orders of magnitude apart under different conditions. If a real figure matters for your work, take it from a source you can cite and check it before use.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What is the difference between heat flux and heat flux density?<\/summary><div class=\"pf-faq-item-answer\">\n\nThey are two names for one quantity, and neither carries any extra meaning. The word density signals the per-unit-area part of the definition, which heat flux already implies, so both describe a flow of energy per unit area per unit time measured in W\/m\u00b2. If a document hands you a heat flux density, treat it as a heat flux and use the same formula.\n\n<\/div><\/details>\n","protected":false},"excerpt":{"rendered":"<p>Heat flux units are watts per square metre, W\/m2, because a heat flux is a power spread over an area rather than a power. The quantity that catches people out is the heat transfer rate: a brick wall at 20 K across 0.160 m carries 90 W\/m2 whether it is one square metre or twelve, but the rate through it rises from 90 W to 1080 W. This guide defines the flux, takes the unit apart to kg\/s3, converts all eight flux units from exactly defined factors, shows why the area cancels, and works eight problems with every step shown.<\/p>\n","protected":false},"author":1,"featured_media":2454,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"class_list":["post-2452","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-thermodynamics"],"_links":{"self":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2452","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/comments?post=2452"}],"version-history":[{"count":3,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2452\/revisions"}],"predecessor-version":[{"id":2463,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2452\/revisions\/2463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media\/2454"}],"wp:attachment":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media?parent=2452"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/categories?post=2452"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/tags?post=2452"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}