{"id":2219,"date":"2026-10-20T13:31:43","date_gmt":"2026-10-20T13:31:43","guid":{"rendered":"https:\/\/physicsfundamentalsinfo.com\/blog\/?p=2219"},"modified":"2026-10-20T13:31:45","modified_gmt":"2026-10-20T13:31:45","slug":"flow-rate-formula","status":"publish","type":"post","link":"https:\/\/physicsfundamentalsinfo.com\/blog\/fluids\/flow-rate-formula\/","title":{"rendered":"Flow Rate Formula (Q = Av)"},"content":{"rendered":"\n<div class=\"pf-citation\"><div class=\"eyebrow\">Definition<\/div><p>\n\nThe flow rate formula is Q = A v: the volume of fluid crossing a fixed section each second equals the area open to the flow multiplied by the mean speed of the fluid. Its SI unit is the cubic metre per second. One rate therefore fixes a different speed in every bore a pipe has.\n\n<\/p><\/div>\n\n<p>Turn a garden hose on and the water leaves in a lazy arc. Pinch the end with your thumb and it snaps into a jet that reaches the far hedge. Nothing has been added at the tap \u2014 the same litres per second are leaving, through a smaller hole.<\/p>\n\n<p>That swap is the whole of this page. A flow rate ties an area to a speed, so once the rate is fixed the pipe decides the rest: a narrow section has to run fast, and a wide one is allowed to loiter.<\/p>\n\n<h2>What Is the Flow Rate Formula?<\/h2>\n\n<p>The flow rate formula, Q = A v, says that the volume of fluid passing a fixed section each second is the cross-sectional area of that section times the mean speed of the fluid through it.<\/p>\n\n<p>Think about one second of flow. Whatever gets past the section in that second is a slug of fluid shaped like the pipe, and its length is just how far the fluid travelled. Divide that volume by the second it took and you have a rate.<\/p>\n\n<p>Most of the time nobody hands you an area. You are handed a diameter, which is why A = pi d<sup>2<\/sup> \/ 4 belongs in the same breath as the formula itself. That same circle turns up elsewhere as the area <a href=\"\/blog\/fluids\/pressure-in-physics\/\">a pressure acts on<\/a>; here it is the doorway the fluid has to get through, and it is the step most wrong answers die on.<\/p>\n\n<p>One warning about the letter, before any arithmetic. Q counts litres here, not joules: in <a href=\"\/blog\/thermodynamics\/fouriers-law\/\">Fourier&#8217;s law of heat conduction<\/a> the same symbol carries a flow of heat in watts. Same letter, different quantity, and nothing on this page is an energy.<\/p>\n\n<figure style=\"margin:32px auto;max-width:640px;text-align:center;\">\n  <img decoding=\"async\" src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/a-water-meter-or-inline-flow-meter-on-a-visible-pipe.jpg\"\n       alt=\"Water meter fitted into a pipe, the instrument that measures what the flow rate formula predicts\"\n       loading=\"lazy\"\n       style=\"width:100%;height:auto;border-radius:4px;\" width=\"897\" height=\"342\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">A meter on a pipe. The bore it is fitted to and the mean speed of the water through it are the only two numbers Q = A v needs.<\/figcaption>\n<\/figure>\n\n<h2>How to Use the Q = Av Formula, Step by Step<\/h2>\n\n<p>Three numbers and one multiplication: take the bore, turn it into an area, then multiply by the mean speed.<\/p>\n\n<div class=\"pf-formula\">Q = A v<\/div>\n\n<div class=\"pf-formula\">A = pi d^2 \/ 4   \u2014   for a round pipe of internal diameter d<\/div>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Symbol<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">What it is<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">SI unit<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">A 100 mm pipe at 1.50 m\/s<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>Q<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Volume flow rate: the volume crossing a fixed section each second<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">cubic metre per second (m<sup>3<\/sup>\/s)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.0117810 m<sup>3<\/sup>\/s, or 11.7810 L\/s<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>A<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Cross-sectional area open to the flow<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">square metre (m<sup>2<\/sup>)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.00785398 m<sup>2<\/sup><\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>v<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Mean speed of the fluid across that section \u2014 an average, not a reading from the middle<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">metre per second (m\/s)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1.50 m\/s<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>d<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Internal diameter of a round pipe \u2014 the inside bore, not a nominal size<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">metre (m)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">100 mm, which is 0.100 m<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>rho<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Density of the fluid, needed only for the mass flow rate<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">kilogram per cubic metre (kg\/m<sup>3<\/sup>)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">998.2 for water at 20 C<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>mdot<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Mass flow rate, the kilograms crossing that section each second<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">kilogram per second (kg\/s)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7598 kg\/s<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>V<\/strong> and <strong>t<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">A volume to be passed, and the time it takes at that rate<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">cubic metre (m<sup>3<\/sup>) and second (s)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">100 L in 8.48826 s<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Now put that pipe through the formula, because arithmetic is easier to trust once you have watched it land. A 100 mm bore gives an area of 0.00785398 m<sup>2<\/sup>, and at a mean speed of 1.50 m\/s that is 0.0117810 m<sup>3<\/sup>\/s \u2014 11.7810 litres every second.<\/p>\n\n<p>Type those same two boxes into the <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/flow-rate-formula\">flow rate calculator<\/a> and it returns 11.78 L\/s at its four-figure precision, with the area, the mass flow rate and the fill time printed beside the answer. It will also run the question backwards, which is what you want when the bore is the unknown.<\/p>\n\n<p>One slip accounts for most wrong answers here, and the area is why. A bore typed in millimetres into a formula that wants metres is out by a factor of a thousand, and squaring it makes the area out by a million. Convert first; multiply second.<\/p>\n\n<figure style=\"margin:32px auto;max-width:720px;text-align:center;\">\n  <img src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-01-768x356.jpg\" srcset=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-01-768x356.jpg 768w, https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-01.jpg 1920w\" sizes=\"auto, (max-width: 760px) 100vw, 720px\" width=\"1920\" height=\"891\" alt=\"A diagram in two parts showing that a flow rate is a volume swept past a section every second. On the left, the circular cross-section of a 100 mm bore pipe is drawn with a diameter dimension line labelled d = 100 mm, the circle shaded gold and annotated A = pi d^2 \/ 4 = 0.00785398 m2. On the right, the same pipe is drawn in side elevation to the same bore scale, with a gold slug of fluid filling it, a break symbol showing that its length is foreshortened, a flow arrow along the axis labelled v = 1.50 m\/s, and a note that the swept volume equals the area times 1.50 m, which is 0.0117810 m3. A dimension line beneath the pipe is labelled 1.50 m, how far the fluid moves in one second, foreshortened. Underneath, the headline reads Q = A v = 0.0117810 m3\/s = 11.7810 L\/s, with a footnote that the same rate is 706.858 L\/min or 42.4115 m3\/h and that each figure is the one rate to six significant figures.\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:4px;\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Figure 1: the area is a doorway and the speed is how fast the fluid walks through it. One second of walking sweeps the gold slug, and that volume per second is Q.<\/figcaption>\n<\/figure>\n\n<p>Here is the same pipe as something you can push around. The step in it is the whole point: everything upstream sets the rate, and the bore downstream only decides how fast that rate has to travel.<\/p>\n\n<div class=\"pf-sim-slot\"><div class=\"pf-sim-slot-header\"><span class=\"icon-dot\"><\/span><span class=\"label\">Flow Rate Formula Lab<\/span><\/div><div class=\"pf-sim-slot-body\"><style>.pf-sim-frame{width:100%;border:none;height:900px}@media(max-width:760px){.pf-sim-frame{height:1900px}}<\/style><iframe src=\"\/labs\/flow-rate-formula.html?embed=1\" class=\"pf-sim-frame\" loading=\"lazy\"><\/iframe><\/div><\/div>\n\n<h2>Flow Rate Units: L\/s, L\/min and m3\/h<\/h2>\n\n<p>The SI unit of flow rate is the cubic metre per second, m<sup>3<\/sup>\/s, and every other unit you meet is that same quantity rescaled. Litres per second, litres per minute and cubic metres per hour are the three that do the day-to-day work.<\/p>\n\n<p>One rate, four ways of writing it. The 100 mm pipe above runs at 0.0117810 m<sup>3<\/sup>\/s, and that is 11.7810 L\/s, 706.858 L\/min and 42.4115 m<sup>3<\/sup>\/h \u2014 four strings, one flow.<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Unit<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">One of it, in m<sup>3<\/sup>\/s<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">The 100 mm pipe at 1.50 m\/s<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Where you meet it<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>m<sup>3<\/sup>\/s<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1 (the SI unit)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.0117810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Physics and engineering working; every conversion passes through it<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>L\/s<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.001<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Taps, hoses, laboratory rigs, fire-flow figures<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>L\/min<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1\/60000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">706.858<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Pump curves, flow meters, shower and boiler ratings<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>m<sup>3<\/sup>\/h<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1\/3600<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">42.4115<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">Water mains, ventilation ducts, process plant<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Two conversions carry most of the traffic: 1 L\/s is 60 L\/min, and 1 L\/s is 3.6 m<sup>3<\/sup>\/h. Going the other way, divide by the same numbers.<\/p>\n\n<p>Watch what happens if you convert from a figure you have already rounded. The printed 11.7810 L\/s times 60 gives 706.860 L\/min, where the unrounded rate gives 706.858 \u2014 the sixth digit is wrong because the rounding came first. Carry the full rate through the conversion, then round once, at the end.<\/p>\n\n<p>Other trades keep the same formula and swap the labels. The US Geological Survey computes a river&#8217;s <a href=\"https:\/\/www.usgs.gov\/special-topics\/water-science-school\/science\/how-streamflow-measured\" target=\"_blank\" rel=\"noopener\">discharge<\/a> by &#8220;multiplying the area of water in a channel cross section by the average velocity of the water in that cross section&#8221;, and then quotes it in cubic feet per second or gallons per day. The relation is Q = A v; only the units on the answer have changed.<\/p>\n\n<h2>Why a Narrower Pipe Means a Faster Flow<\/h2>\n\n<p>A narrower section runs faster because the rate reaching it was already fixed upstream, and the only way the same volume per second fits through a smaller opening is to cross it more quickly.<\/p>\n\n<p>Nothing is stored at a step in a pipe and nothing leaks out of it. So the volume arriving each second has to be the volume leaving each second, which gives continuity its plainest form.<\/p>\n\n<div class=\"pf-formula\">A1 v1 = A2 v2   \u2014   one rate, measured at any two stations<\/div>\n\n<div class=\"pf-formula\">v2 = v1 (d1 \/ d2)^2   \u2014   for round pipes<\/div>\n\n<p>That exponent is where most answers go wrong. Area follows the square of the diameter, so halving the bore quarters the area and the speed must go up four times, not two.<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Downstream bore<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Area there (m<sup>2<\/sup>)<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Mean speed there (m\/s)<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Flow rate (L\/s)<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">What the lab prints<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">100 mm (no step)<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.00785398<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1.50000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>11.7810<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">same area, same speed<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">50 mm<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.00196350<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">6.00000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>11.7810<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">area 4.00000x smaller, speed 4.00000x faster<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">20 mm<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.000314159<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">37.5000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>11.7810<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">area 25.0000x smaller, speed 25.0000x faster<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">200 mm<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.0314159<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">0.375000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>11.7810<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">area 4.00000x larger, speed 4.00000x slower<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Read down the rate column and nothing moves. Four very different downstream bores, four very different speeds, one rate \u2014 because the rate was decided by the 100 mm inlet and its 1.50 m\/s, and the step downstream was never consulted.<\/p>\n\n<p>The two factors are exactly reciprocal, and that is worth taking literally. Work them from the bores in whole millimetres, where (100\/50)<sup>2<\/sup> is exactly 4, and the area factor and the speed factor are the same number to every digit printed; divide the two rounded areas instead and you get 3.99999, which is the rounding talking, not the physics.<\/p>\n\n<p>One thing this section deliberately does not do is tell you what the pressure does across that step. That belongs to <a href=\"\/blog\/fluids\/bernoullis-principle\/\">Bernoulli&#8217;s principle<\/a>, which trades speed against pressure along a streamline; nothing on this page computes a pressure at all.<\/p>\n\n<figure style=\"margin:32px auto;max-width:720px;text-align:center;\">\n  <img src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-02-768x373.jpg\" srcset=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-02-768x373.jpg 768w, https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/flow-rate-formula-diagram-02.jpg 1920w\" sizes=\"auto, (max-width: 760px) 100vw, 720px\" width=\"1920\" height=\"933\" alt=\"A side view of one pipe with an abrupt step from a 100 mm bore on the left to a 50 mm bore on the right, both drawn to one scale of 120 pixels to 100 mm, with the flow running left to right. A single label spanning the step reads Q = 11.7810 L\/s, the same rate on both sides of the step, with an arrow pointing downstream. The wide section is labelled d1 = 100 mm and v1 = 1.50 m\/s and carries eight evenly spaced tracer marks 44 pixels apart; the narrow section is labelled d2 = 50 mm and v2 = 6.00 m\/s and carries three tracer marks 176 pixels apart, four times farther apart than in the wide section. A bracket under one gap in each section compares the two spacings, captioned that equal volumes pass between consecutive marks so the gap is 4.00000 times longer where the speed is 4.00000 times higher. The headline underneath reads A1 v1 = A2 v2, so an area 4.00000x smaller means a speed 4.00000x faster, with a footnote giving the two areas as 0.00785398 m2 and 0.00196350 m2, the rate as 0.0117810 m3\/s at both stations, and a note that the figure computes no pressure.\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:4px;\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Figure 2: the tracer marks are released at a steady rate, so the same volume of water sits between any two of them. That is why they stretch apart in the fast narrow bore instead of crowding together.<\/figcaption>\n<\/figure>\n\n<h2>Mass Flow Rate: When Kilograms Matter, Not Litres<\/h2>\n\n<p>Mass flow rate is the density times the volume flow rate, mdot = rho Q, and it is the figure you want whenever what is being paid for, heated or lifted is measured in kilograms rather than litres.<\/p>\n\n<div class=\"pf-formula\">mdot = rho Q   \u2014   mass flow rate (kg\/s) = density (kg\/m3) x volume flow rate (m3\/s)<\/div>\n\n<p>NASA&#8217;s Glenn Research Center builds it from the same swept slug this page started with: &#8220;If the fluid initially passes through an area A at velocity V, we can define a volume of mass to be swept out in some amount of time t&#8221;, and dividing that mass by the time gives the <a href=\"https:\/\/www1.grc.nasa.gov\/beginners-guide-to-aeronautics\/mass-flow-rate\/\" target=\"_blank\" rel=\"noopener\">mass flow rate<\/a>. Volume first, then density.<\/p>\n\n<p>Keep the pipe and the speed fixed, change only the fluid, and see what moves.<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Fluid<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Density (kg\/m<sup>3<\/sup>)<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Flow rate (L\/s)<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Mass flow rate (kg\/s)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">Water at 20 C<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">998.2<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>11.7598<\/strong><\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">Air at 20 C<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1.204<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>0.0141843<\/strong><\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">Glycerine<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">1261<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>14.8558<\/strong><\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;\">SAE 30 oil at 40 C<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">876<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">11.7810<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\"><strong>10.3201<\/strong><\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>The rate column never moves: the volume per second is the same for all four, because Q never asked what was flowing. The mass column runs from 0.0141843 kg\/s to 14.8558 kg\/s, because the densities behind it run from 1.204 kg\/m<sup>3<\/sup> for air to 1261 kg\/m<sup>3<\/sup> for glycerine \u2014 more than a thousandfold. That spread is the whole reason a gas is metered by mass and not by volume.<\/p>\n\n<p>Air makes the point loudest. A 200 mm duct at 5.00 m\/s moves 157.080 L\/s, which sounds like a lot until you weigh it: 0.189124 kg\/s, less than a fifth of a kilogram a second. Get the <a href=\"\/blog\/fluids\/density-formula\/\">density<\/a> wrong and the mass flow rate is wrong by exactly that factor, however good the geometry was.<\/p>\n\n<h2>How Long Will It Take to Fill?<\/h2>\n\n<p>Divide the volume by the rate: t = V \/ Q. A rate is a volume per second, so a volume divided by it comes back as a time.<\/p>\n\n<div class=\"pf-formula\">t = V \/ Q   \u2014   time (s) = volume (m3) \/ volume flow rate (m3\/s)<\/div>\n\n<p>At the 11.7810 L\/s this page keeps returning to, 100 litres is gone in 8.48826 s. Scale the pipe down to something domestic and the arithmetic stops being abstract: a 15 mm pipe at 1.00 m\/s carries 0.176715 L\/s, or 10.6029 L\/min.<\/p>\n\n<p>That same 15 mm pipe takes 56.5884 s to deliver 10 litres and 9.43140 min to deliver 100. Watch the unit switch rather than the digits: 254.648 s is easier to act on written as 4.24413 min, and at the slowest rate the lab can reach, 1000 litres needs 35.3678 h.<\/p>\n\n<p>One honest caveat. The division assumes the rate holds steady for the whole fill, which is true of a pump on its duty point and false of a tank emptying under its own falling level \u2014 in that case treat the answer as a first estimate and expect the real time to be longer.<\/p>\n\n<h2>Where the Flow Rate Formula Breaks Down<\/h2>\n\n<p>Q = A v is kinematics: it counts volume crossing a section and says nothing about what it would take to drive that flow. Four limits follow from that, and the first and the last are the ones that cost marks.<\/p>\n\n<ul>\n<li><strong>It knows nothing about pressure.<\/strong> The formula will happily hand you a speed that no real pump could produce, because no pressure appears in it anywhere. The speed-against-pressure trade is <a href=\"\/blog\/fluids\/bernoullis-principle\/\">Bernoulli&#8217;s<\/a> department, not this one.<\/li>\n<li><strong>It assumes the density does not change.<\/strong> One rate at every station is a statement about volume, and it only survives while the fluid is incompressible. For a gas that means well below the speed of sound, 343 m\/s in air; the lab applies the same test to water at 1480 m\/s, and once a downstream speed crosses the threshold for the fluid you have picked it says so out loud, printing &#8220;Past the speed of sound in air &#8211; the incompressible rule has gone&#8221;.<\/li>\n<li><strong>Two of the lab&#8217;s fluids carry no such warning, and that is deliberate.<\/strong> This site publishes no speed of sound for glycerine or for SAE 30 oil, so no threshold exists for them and none was invented. Treat extreme states in those two fluids as unchecked arithmetic.<\/li>\n<li><strong>v is a mean, not the fastest speed in the pipe.<\/strong> The v in Q = A v is the average speed across the whole section, so do not put a single probe reading into it and expect the rate; how the speed varies across a real pipe is a <a href=\"\/blog\/fluids\/reynolds-number\/\">Reynolds number<\/a> question, not this formula&#8217;s. And when it is viscosity and a pressure drop that set the rate rather than a pump holding a speed, the law you need is Poiseuille&#8217;s, covered with <a href=\"\/blog\/fluids\/viscosity-units-examples\/\">viscosity<\/a> rather than here.<\/li>\n<\/ul>\n\n<h2>Common Misconceptions About Flow Rate<\/h2>\n\n<h3>&#8220;Halving the diameter halves the speed&#8221;<\/h3>\n\n<p>It quadruples it. The area carries the square of the diameter, so half the bore is a quarter of the area, and a quarter of the doorway at the same rate needs four times the speed. The 50 mm row in the table above is that arithmetic: 1.50 m\/s becomes 6.00000 m\/s.<\/p>\n\n<h3>&#8220;A bigger pipe gives you a faster flow&#8221;<\/h3>\n\n<p>At the same flow rate, a bigger pipe gives you a slower one. Widen the 100 mm section to 200 mm and the water drops from 1.50 m\/s to 0.375000 m\/s while the rate stays at 11.7810 L\/s. A bigger pipe lets you carry more \u2014 it does not make what you already have travel faster.<\/p>\n\n<h3>&#8220;Flow rate and flow speed are the same thing&#8221;<\/h3>\n\n<p>They are different quantities with different units: a rate is measured in m<sup>3<\/sup>\/s, a speed in m\/s. The area is what converts one into the other, which is why a figure like &#8220;6 m\/s&#8221; tells you nothing about how much water is arriving until someone tells you the bore.<\/p>\n\n<h3>&#8220;The narrow section must be carrying less water&#8221;<\/h3>\n\n<p>It carries exactly the same amount per second. Nothing is stored at the step and nothing escapes, so every litre that enters the wide section leaves through the narrow one \u2014 faster, but not in smaller quantity. That identity is the point of the whole page.<\/p>\n\n<h3>&#8220;Q means heat&#8221;<\/h3>\n\n<p>Not here. The same letter does duty for a heat flow in other corners of physics, and a <a href=\"\/blog\/thermodynamics\/fouriers-law\/\">heat flow rate<\/a> is measured in watts, not cubic metres per second. On this page Q is a volume crossing a section each second, and nothing on it is an energy.<\/p>\n\n<h2>Worked Problems<\/h2>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 1<\/div><div class=\"pf-problem-question\">Water flows through a 50 mm internal-diameter pipe at a mean speed of 2.0 m\/s. Find the flow rate in m3\/s and L\/s, then give it in the units a pump is sold in: L\/min and m3\/h.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: the area of the bore. A = pi d^2 \/ 4 = pi x (0.050 m)^2 \/ 4 = 0.00196350 m2.\n\nStep 2: the rate. Q = A v, with the area carried at full precision rather than at the six figures printed above, which gives Q = 0.00392699 m3\/s. (Multiply the rounded 0.00196350 by 2.0 instead and you get 0.00392700 \u2014 a last-digit error from rounding too early.)\n\nStep 3: into litres. 1 m3 is 1000 L, so Q = 3.92699 L\/s.\n\nStep 4: into pump units. 3.92699 x 60 = 235.619 L\/min, and 3.92699 x 3.6 = 14.1372 m3\/h.\n\n<strong>Answer: Q = 0.00392699 m3\/s = 3.92699 L\/s = 235.619 L\/min = 14.1372 m3\/h.<\/strong> One rate; four labels. The L\/min figure is the one a pump catalogue will recognise.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 2<\/div><div class=\"pf-problem-question\">A meter reads 0.30 L\/s through a 25 mm internal-diameter pipe. What is the mean speed of the water?<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: get both quantities into SI. 0.30 L\/s = 0.000300 m3\/s, and d = 25 mm = 0.025 m.\n\nStep 2: the area. A = pi x (0.025 m)^2 \/ 4 = 0.000490874 m2.\n\nStep 3: rearrange Q = A v for the speed. v = Q \/ A = 0.000300 \/ 0.000490874 = 0.611155 m\/s.\n\n<strong>Answer: v = 0.611155 m\/s<\/strong>, about 0.61 m\/s. A rate alone never gives you a speed \u2014 the bore has to be in the sum.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 3<\/div><div class=\"pf-problem-question\">A system must carry 12 L\/s and the design mean speed is 1.8 m\/s. What internal diameter does that need, and what happens if you fit the next standard size up, a 100 mm pipe?<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: the area the duty needs. Q = 12 L\/s = 0.012 m3\/s, so A = Q \/ v = 0.012 \/ 1.8 = 0.00666667 m2.\n\nStep 2: turn the area back into a diameter. A = pi d^2 \/ 4 rearranges to d = sqrt(4A \/ pi), and 4 x 0.00666667 \/ pi = 0.00848827 m2.\n\nStep 3: take the root. d = sqrt(0.00848827) = 0.0921318 m = 92.1318 mm.\n\nStep 4: fit the 100 mm pipe instead and recompute the speed at the same duty. v = Q \/ A = 0.012 \/ 0.00785398 = 1.52789 m\/s.\n\n<strong>Answer: the duty needs a 92.1318 mm bore; a 100 mm pipe carries the same 12 L\/s at 1.52789 m\/s.<\/strong> Note the direction of that change: the wider pipe runs <em>slower<\/em> than the design speed, not faster. Going up a size always buys you a gentler flow, never a brisker one.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 4<\/div><div class=\"pf-problem-question\">Water enters a 100 mm pipe at a mean speed of 1.2 m\/s and the pipe steps down to 40 mm. Find the flow rate and the mean speed in the 40 mm section, then check the answer a second way.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: the rate, set entirely by the inlet. A1 = 0.00785398 m2, so Q = A1v1 = 0.00785398 x 1.2 = 0.00942478 m3\/s = 9.42478 L\/s.\n\nStep 2: the speed-up, straight from the diameters. v2 = v1(d1\/d2)^2, and (100\/40)^2 = 6.25000 exactly, so v2 = 1.2 x 6.25 = 7.50000 m\/s.\n\nStep 3: check it from the area instead. A2 = pi x (0.040 m)^2 \/ 4 = 0.00125664 m2, and Q \/ A2 with both values unrounded returns 7.50000 m\/s. (Divide the two rounded six-figure numbers and you get 7.49998 \u2014 agreement to five figures, and a reminder to round last.)\n\n<strong>Answer: Q = 9.42478 L\/s and v2 = 7.50000 m\/s.<\/strong> The rate never asked about the 40 mm section; only the speed did.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 5<\/div><div class=\"pf-problem-question\">Air at 20 C flows along a 300 mm duct at a mean speed of 6.0 m\/s. Find the volume flow rate and the mass flow rate, and say what the same volume rate of water would weigh per second.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: the area. A = pi x (0.300 m)^2 \/ 4 = 0.0706858 m2.\n\nStep 2: the volume rate. Q = A v = 0.0706858 x 6.0 = 0.424115 m3\/s, which is 424.115 L\/s.\n\nStep 3: bring in the density. Air at 20 C is 1.204 kg\/m3, so mdot = rho Q = 1.204 x 0.424115 = 0.510634 kg\/s.\n\nStep 4: the same volume rate of water, at 998.2 kg\/m3. mdot = 998.2 x 0.424115 = 423.352 kg\/s.\n\n<strong>Answer: Q = 0.424115 m3\/s, and mdot = 0.510634 kg\/s of air.<\/strong> The duct shifts nearly half a cubic metre a second and just over half a kilogram with it; the same volume rate of water would be 423.352 kg\/s. Geometry sets the volume, density sets the mass.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 6<\/div><div class=\"pf-problem-question\">A 20 mm hose runs at a mean speed of 2.5 m\/s into a 200 litre tank. How long does the tank take to fill?<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: the area. A = pi x (0.020 m)^2 \/ 4 = 0.000314159 m2.\n\nStep 2: the rate. Q = A v = 0.000314159 x 2.5 = 0.000785398 m3\/s = 0.785398 L\/s.\n\nStep 3: the time. V = 200 L = 0.200 m3, so t = V \/ Q = 0.200 \/ 0.000785398 = 254.648 s.\n\nStep 4: give it in a unit a person can use. 254.648 \/ 60 = 4.24413 min.\n\n<strong>Answer: t = 254.648 s, or 4.24413 min.<\/strong> Under five minutes, and the answer holds only while the hose keeps delivering that same 0.785398 L\/s.\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 7<\/div><div class=\"pf-problem-question\">Open the lab above at its starting state: a 100 mm inlet at 1.50 m\/s, stepping down to 50 mm, with a 100 litre vessel and water. Read the four cards, then prove from them that the area and speed factors really are reciprocal.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: leave every slider where it boots and read the four cards. The rate card gives 11.7810 L\/s. Below it: 6.00000 m\/s downstream, 11.7598 kg\/s of water, and 8.48826 s to put 100 litres in the vessel.\n\nStep 2: move the downstream slider alone, from 50 mm to 20 mm, and watch which numbers answer. The speed card jumps to 37.5000 m\/s; the rate card does not move off 11.7810 L\/s, because the downstream bore appears nowhere in Q = A1v1.\n\nStep 3: put the 50 mm section back and compare the two factors. The bores give an area factor of (100\/50)^2 = 4.00000, and the speeds give 6.00000 \/ 1.50 = 4.00000 \u2014 which is why the lab&#8217;s own row reads &#8220;area 4.00000x smaller, speed 4.00000x faster &#8211; exactly reciprocal&#8221;.\n\n<strong>Answer: 11.7810 L\/s, 6.00000 m\/s, 11.7598 kg\/s and 8.48826 s, with the area and speed factors both 4.00000.<\/strong> Each card answers to a different control, and only the rate refuses to move when the step does.\n\n<\/div><\/details><\/div>\n\n<h2>Frequently Asked Questions<\/h2>\n\n<details class=\"pf-faq-item\"><summary>What is the flow rate formula?<\/summary><div class=\"pf-faq-item-answer\">\n\nThe flow rate formula is Q = A v: the volume flow rate equals the cross-sectional area open to the flow times the mean speed of the fluid through it. Q is in cubic metres per second, A in square metres and v in metres per second. For a round pipe of internal diameter d, the area is pi d^2 \/ 4.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>How do you calculate flow rate from pipe diameter?<\/summary><div class=\"pf-faq-item-answer\">\n\nConvert the diameter to metres, square it, multiply by pi and divide by four to get the area, then multiply by the mean speed. A 100 mm pipe gives an area of 0.00785398 m2, and at 1.50 m\/s that is 0.0117810 m3\/s, or 11.7810 L\/s. Forgetting to convert millimetres to metres is the most common error, and squaring multiplies it.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What are the units of flow rate?<\/summary><div class=\"pf-faq-item-answer\">\n\nThe SI unit of flow rate is the cubic metre per second, m3\/s. In practice the same rate is quoted in litres per second, litres per minute or cubic metres per hour: 1 L\/s is 60 L\/min and 3.6 m3\/h. So 0.0117810 m3\/s, 11.7810 L\/s, 706.858 L\/min and 42.4115 m3\/h are one flow written four ways.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Why does a narrower pipe make the water faster?<\/summary><div class=\"pf-faq-item-answer\">\n\nBecause the flow rate was fixed before the water reached the narrow section. The same volume per second has to cross a smaller area, so it must cross it faster, and the speed rises as the square of the diameter ratio. Step a 100 mm pipe at 1.50 m\/s down to 50 mm and the speed becomes 6.00000 m\/s while the rate stays at 11.7810 L\/s.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What is the difference between flow rate and flow speed?<\/summary><div class=\"pf-faq-item-answer\">\n\nFlow rate is a volume per unit time, measured in m3\/s; flow speed is a distance per unit time, measured in m\/s. The cross-sectional area links them through Q = A v, so a single speed corresponds to many different rates depending on the bore. A speed alone never tells you how much fluid is arriving.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>How do you work out mass flow rate?<\/summary><div class=\"pf-faq-item-answer\">\n\nMultiply the volume flow rate by the density of the fluid: mdot = rho Q, in kilograms per second. At 11.7810 L\/s, water at 998.2 kg\/m3 gives 11.7598 kg\/s, while air at 1.204 kg\/m3 gives only 0.0141843 kg\/s. Same pipe, same rate, two mass flows more than eight hundredfold apart, which is why gases are metered by mass.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>How long will it take to fill a tank?<\/summary><div class=\"pf-faq-item-answer\">\n\nDivide the volume by the flow rate: t = V \/ Q. A 200 litre tank fed at 0.785398 L\/s takes 254.648 s, which is 4.24413 min. The answer is only as steady as the rate: a pump holding its duty point gives a reliable time, whereas a tank filling from a falling level slows down and takes longer than the division suggests.\n\n<\/div><\/details>\n","protected":false},"excerpt":{"rendered":"<p>The flow rate formula is Q = Av: the volume crossing a fixed section each second is the area open to the flow times the mean speed of the fluid. This page takes a 100 mm pipe at 1.50 m\/s through it to 11.7810 L\/s, gives the same rate as 0.0117810 m3\/s, 706.858 L\/min and 42.4115 m3\/h, shows why a step down to 50 mm forces 6.00000 m\/s while the rate never moves, adds mass flow rate and fill time, states the honest limits, and works seven problems in full.<\/p>\n","protected":false},"author":1,"featured_media":2222,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[160],"tags":[],"class_list":["post-2219","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fluids"],"_links":{"self":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/comments?post=2219"}],"version-history":[{"count":3,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2219\/revisions"}],"predecessor-version":[{"id":2251,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2219\/revisions\/2251"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media\/2222"}],"wp:attachment":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media?parent=2219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/categories?post=2219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/tags?post=2219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}