{"id":2149,"date":"2026-10-05T12:06:36","date_gmt":"2026-10-05T12:06:36","guid":{"rendered":"https:\/\/physicsfundamentalsinfo.com\/blog\/?p=2149"},"modified":"2026-10-05T12:06:37","modified_gmt":"2026-10-05T12:06:37","slug":"magnetic-flux","status":"publish","type":"post","link":"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/magnetic-flux\/","title":{"rendered":"Magnetic Flux: Formula, Units and Worked Examples"},"content":{"rendered":"\n<div class=\"pf-citation\"><div class=\"eyebrow\">Definition<\/div><p>\n\nMagnetic flux is the total magnetic field passing through a surface: the flux density multiplied by\nthe area and by the cosine of the angle between the field and the surface\u2019s normal. Its SI\nunit is the weber, and one weber is one tesla square metre. Turn the surface edge-on and the flux\nis zero.\n\n<\/p><\/div>\n\n<p>Stand a bicycle wheel in a doorway and ask how much wind blows through it. Square to the gust, the whole wheel catches it; turn the rim into the wind and nothing goes through at all. Magnetic flux asks that question of a magnetic field, and the answer is a number in webers.<\/p>\n\n<p>The formula is short. All of the difficulty sits in one letter: \u03b8 is not the angle between the field and the surface, it is the angle between the field and the line sticking straight out of the surface. Confusing those two is the single commonest way a flux calculation goes wrong, and this page works both answers out so you can see the size of the gap.<\/p>\n\n<h2>What Is Magnetic Flux, and What Does the Weber Measure?<\/h2>\n\n<p>Magnetic flux is a count of how much magnetic field threads a given surface, and the weber is the unit that count comes in: one weber is one tesla of flux density spread over one square metre.<\/p>\n\n<p>Picture the field as a bundle of parallel lines running through space. The flux through a loop is, loosely, how many of those lines pass through the hole. Loosely, because lines are a drawing convention rather than countable objects \u2014 but the intuition is exactly right, and it is why a bigger loop, a stronger field or a squarer orientation all give you more flux.<\/p>\n\n<p>Two quantities are easy to run together here. <strong>B<\/strong> is the <em>flux density<\/em>, measured in tesla, and it describes the field at a single point; our guide to the <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/magnetic-field\/\">magnetic field<\/a> covers where B comes from and what it does to a moving charge. <strong>\u03a6<\/strong> is the <em>flux<\/em>, measured in webers, and it is a total over a whole surface.<\/p>\n\n<p>Why does anyone want the number at all? Because a flux that <em>changes<\/em> is what drives a current round a circuit \u2014 that is Faraday&#8217;s law, and <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/faradays-law-formula\/\">the Faraday&#8217;s law formula<\/a> owns that relation in full. Nothing on this page changes with time, so no voltage is computed here; the flux is the ingredient, not the dish.<\/p>\n\n<h3>The weber, three ways<\/h3>\n\n<ul>\n<li><strong>1 Wb = 1 T m<sup>2<\/sup><\/strong> \u2014 a flux density of one tesla spread over one square metre. This is the form you use for every calculation on this page.<\/li>\n<li><strong>1 T = 1 Wb\/m<sup>2<\/sup><\/strong> \u2014 the same identity read backwards, which is why B is called a flux <em>density<\/em>.<\/li>\n<li><strong>1 Wb = 1 V s<\/strong> \u2014 a unit identity that comes from Faraday&#8217;s law. It is true, and deriving it is that page&#8217;s job, not this one&#8217;s.<\/li>\n<\/ul>\n\n<p>School-sized loops in school-sized fields land in the milliweber range, so expect answers with &#8220;m&#8221; in front of the unit. A microweber or two is perfectly ordinary for a small coil in a weak field.<\/p>\n\n<h2>The Magnetic Flux Formula and Every Symbol in It<\/h2>\n\n<p>For a flat surface in a uniform field, the whole of magnetic flux is one line of algebra.<\/p>\n\n<div class=\"pf-formula\">\u03a6 = B A cos \u03b8<\/div>\n\n<ul>\n<li><strong>\u03a6<\/strong> \u2014 the magnetic flux through the surface, in webers (Wb).<\/li>\n<li><strong>B<\/strong> \u2014 the magnetic flux density, in tesla (T). One tesla is enormous as fields go; the magnet on a fridge door manages a few millitesla.<\/li>\n<li><strong>A<\/strong> \u2014 the area of the flat surface, in square metres (m<sup>2<\/sup>). Square centimetres must be converted first.<\/li>\n<li><strong>\u03b8<\/strong> \u2014 the angle between the field and the <em>normal<\/em> to the surface, in degrees or radians. Zero means the surface faces the field square on.<\/li>\n<\/ul>\n\n<p>There is no physical constant in that equation, which is unusual and rather pleasant: every answer is exact arithmetic on your own three numbers, with nothing to look up. If you would rather have the arithmetic done and the rearrangements handled for you, our <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/magnetic-flux\">Magnetic Flux Calculator<\/a> solves the same relation for the flux, the flux density, the area or the angle, and prints the working.<\/p>\n\n<h3>Why the angle is measured from the normal<\/h3>\n\n<p>The normal is the line sticking straight out of the surface, at right angles to it. Measure \u03b8 from there and the cosine does what you want: cos 0 = 1 when the loop faces the field square on, and cos 90 = 0 when it is edge-on and nothing gets through.<\/p>\n\n<p>Measure the angle from the loop&#8217;s own plane instead and you have the complement. A loop square across the field reads 90 degrees rather than 0, the sine appears where the cosine belongs, and every answer comes out wrong by a factor you cannot spot from the units. Worked problem 2 below does it both ways on the same loop.<\/p>\n\n<p>Sweeping the angle by hand is the fastest way to make the cosine stop feeling like a fudge factor. Hold the field and the loop fixed in the simulator below, drag the tilt from 0 through 90 and on to 180, and watch the flux fall to nothing and come back the other way. The same sim has its own page at the <a href=\"https:\/\/physicsfundamentalsinfo.com\/labs\/magnetic-flux-simulator\">magnetic flux simulator<\/a> if you would rather open it full width.<\/p>\n\n<div class=\"pf-sim-slot\"><div class=\"pf-sim-slot-header\"><span class=\"icon-dot\"><\/span><span class=\"label\">Magnetic Flux Lab<\/span><\/div><div class=\"pf-sim-slot-body\"><style>.pf-sim-frame{width:100%;border:none;height:900px}@media(max-width:760px){.pf-sim-frame{height:1600px}}<\/style><iframe src=\"\/labs\/magnetic-flux.html?embed=1\" class=\"pf-sim-frame\" loading=\"lazy\"><\/iframe><\/div><\/div>\n\n<h2>How to Work Out a Magnetic Flux in Three Steps<\/h2>\n\n<p>Three steps, in this order, and the units are the only place it ever goes wrong.<\/p>\n\n<ol>\n<li><strong>Get the area into square metres.<\/strong> Square centimetres divide by 10,000, not by 100 \u2014 so 120 cm<sup>2<\/sup> is 0.0120 m<sup>2<\/sup>. For a circle, work out \u03c0r<sup>2<\/sup> first, with r in metres.<\/li>\n<li><strong>Find the angle from the normal.<\/strong> If the problem gives you the tilt from the loop&#8217;s plane, subtract it from 90 before you do anything else. Draw the normal if you are not sure.<\/li>\n<li><strong>Multiply, then name the sense.<\/strong> \u03a6 = B A cos \u03b8 gives you webers. A negative answer is not an error \u2014 it means the field is threading the surface the other way relative to the normal you chose.<\/li>\n<\/ol>\n\n<figure style=\"margin:32px auto;max-width:720px;text-align:center;\">\n  <img src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-01-768x576.jpg\" srcset=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-01-768x576.jpg 768w, https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-01.jpg 1400w\" sizes=\"auto, (max-width: 760px) 100vw, 720px\" width=\"1400\" height=\"1050\" alt=\"A single panel on a cream background showing the geometry of the magnetic flux formula seen from above. Seven evenly spaced navy arrows run horizontally across the panel from left to right, all the same length, under the label B, a uniform flux density, same size and direction everywhere. In the middle a thick gold bar stands for the wire loop seen edge on, leaning down to the right and labelled the loop, seen edge-on. A wine arrow leaves the centre of the bar at right angles to it, pointing up and to the right, labelled normal to the loop. A dashed wine ray leaves the same centre point horizontally to the right, parallel to the field arrows, and a wine arc drawn between that ray and the normal arrow is labelled theta equals 60 deg. On the right of the panel two dashed grey guide lines run horizontally from the two ends of the gold bar to a vertical bracket beside a gold shaded band; that bracket is 100 pixels tall and is labelled, underneath, facing width, w cos theta = 100 px. Further right a second, fainter bracket 200 pixels tall is labelled, underneath, the same loop square on, w = 200 px. Four footnotes state that the view is from above so the loop's other dimension runs into the page and does not change, which makes the facing area A cos theta in the same ratio as the facing width drawn here; that the tilt is drawn to scale, the facing width being exactly half the full width because cos 60 deg is 0.500; and that the angle between the field and the loop's own plane is 30 degrees here, not 60, so swapping the two puts cos 30 equals 0.866 where cos 60 equals 0.500 belongs; and that the dashed ray through the loop's centre is the field direction repeated there, with the arc between it and the normal being theta.\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:4px;\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Figure 1. The loop seen from above, tilted so that the normal sits 60 degrees from the field. The facing width is drawn at exactly half the loop&#8217;s full width, because cos 60 deg = 0.500.<\/figcaption>\n<\/figure>\n\n<p>One sanity check costs nothing and catches most slips. The biggest flux this loop could possibly carry is B A, with the loop square on; if your answer is larger than that, the cosine has been applied upside down. The <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/solenoid\/\">solenoid<\/a> is the usual source of a genuinely uniform field to feed into step three, because the field along the inside of a long winding is very nearly constant.<\/p>\n\n<h2>Flux or Flux Density? The Difference That Trips Everyone Up<\/h2>\n\n<p>Flux density is a field at a point; flux is a total through a surface. The tesla and the weber are not two names for the same measurement, and 1 T = 1 Wb\/m<sup>2<\/sup> is the bridge between them.<\/p>\n\n<p>Here is the test that settles it. Take the same 1.2 mWb and push it through a loop of 30 cm<sup>2<\/sup>, then through a loop of 120 cm<sup>2<\/sup>. The flux is identical in both cases, by construction.<\/p>\n\n<p>The density is not. It comes out at 0.400 T for the small loop and 0.100 T for the large one \u2014 a quarter of the area, four times the density. Worked problem 6 does the arithmetic.<\/p>\n\n<p>Which one a problem wants is usually obvious from the unit it asks for, and occasionally obvious from nothing at all. If a question says &#8220;the field is 0.30 T&#8221; it has handed you a density; if it says &#8220;the flux through the coil is 1.8 mWb&#8221; it has handed you a total. Our <a href=\"https:\/\/physicsfundamentalsinfo.com\/calculators\/magnetic-field\">magnetic field calculator<\/a> works out the flux density inside a solenoid from its winding and current, which is frequently the number you then bring to this formula.<\/p>\n\n<p>One more distinction worth stating plainly. A coil of N turns does not change the flux through the hole \u2014 winding the wire round twice does not make more field pass through it. Multiply that flux by N and you have the quantity <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/faradays-law-formula\/\">the Faraday&#8217;s law page<\/a> calls the flux linkage, which is used for a different purpose. The flux itself belongs to the surface, not to the wire.<\/p>\n\n<h2>What Happens When You Tilt the Loop Past 90 Degrees?<\/h2>\n\n<p>Past 90 degrees the flux changes sign, because the field now arrives at the back of the surface rather than the front; the cosine goes negative and the flux follows it.<\/p>\n\n<p>That sign is a bookkeeping choice, not a fact about the field. Choosing a normal is choosing which face of the loop you are calling the front. Flip your choice and every sign in your working flips with it \u2014 which is why two textbooks can disagree about a sign and both be right.<\/p>\n\n<p>Turn the loop right over, to 180 degrees, and you recover the same size of flux with the opposite sign. At exactly 90 degrees the field runs along the surface instead of through it, nothing threads the loop, and the flux is zero while the flux density is completely unchanged. That last pair is the clearest proof that a flux and a flux density are different animals.<\/p>\n\n<p>Here is the whole sweep, at the fixed flux density and loop area the simulator above opens with.<\/p>\n\n<div class=\"pf-table-scroll\" style=\"display:block;width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:1.5em 0;\">\n<table style=\"width:100%;min-width:560px;border-collapse:collapse;word-break:break-word;\">\n<thead>\n<tr style=\"background:#0A1628;color:#FAF6EE;\">\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Angle from the normal<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;white-space:nowrap;\">Cosine<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Area facing the field<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Flux<\/th>\n<th style=\"padding:10px;text-align:left;border:1px solid #D9CFB8;\">Which way it threads<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">1.000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">50.00 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>1.000 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">out of the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">30 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0.866<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">43.30 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>0.866 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">out of the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">45 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0.707<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">35.36 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>0.707 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">out of the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">60 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0.500<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">25.00 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>0.500 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">out of the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">90 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0.000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">0.00 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>0.000 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">none<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">120 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">-0.500<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">25.00 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>-0.500 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">into the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">150 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">-0.866<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">43.30 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>-0.866 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">into the loop<\/td><\/tr>\n<tr><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">180 deg<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">-1.000<\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\">50.00 cm<sup>2<\/sup><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;white-space:nowrap;\"><strong>-1.000 mWb<\/strong><\/td><td style=\"padding:10px;border:1px solid #D9CFB8;\">into the loop<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<p>Every row is B A cos \u03b8 with B = 0.200 T and A = 50 cm<sup>2<\/sup>, so B A = 1.000 mWb and the flux column is simply that number times the cosine. The &#8220;area facing the field&#8221; column is the size of A cos \u03b8, which is why it reads the same at 60 and at 120 degrees while the flux does not.<\/p>\n\n<figure style=\"margin:32px auto;max-width:720px;text-align:center;\">\n  <img src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-02-768x377.jpg\" srcset=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-02-768x377.jpg 768w, https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/magnetic-flux-diagram-02.jpg 1400w\" sizes=\"auto, (max-width: 760px) 100vw, 720px\" width=\"1400\" height=\"688\" alt=\"Three panels side by side on a cream background, all at the same flux density of 0.200 tesla and the same loop area of 50 square centimetres, each seen from above. In every panel six identical navy arrows run left to right for the uniform field, and a thick gold bar stands for the loop. Panel one, headed square on, draws the bar standing vertically, 120 pixels tall, with a gold shaded band and a bracket of the same 120 pixels beside it labelled 120 px, and prints theta equals 0 deg, cos theta equals 1.000 and flux equals 1.000 milliwebers. Panel two, headed tilted 60 degrees, draws the same bar leaning down to the right so that it spans only 60 pixels across the field, with a shaded band and bracket of 60 pixels labelled 60 px, and prints theta equals 60 deg, cos theta equals 0.500 and flux equals 0.500 milliwebers. Panel three, headed edge-on, draws the bar lying flat along the field between two of the arrows so that it spans nothing across it, with no shaded band and a flat zero-height tick labelled 0 px, and prints theta equals 90 deg, cos theta equals 0.000 and flux equals 0.000 milliwebers. Two footnotes state that two shaded bands are drawn, at 120 px and 60 px, with a zero-height tick in place of the third, the same one to a half to zero ratio as the three fluxes printed under them, and that the field is identical in all three panels: nothing about it has changed and only the loop has turned.\" loading=\"lazy\" decoding=\"async\" style=\"width:100%;height:auto;border-radius:4px;\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">Figure 2. One loop and one field at three tilts. Two shaded bands, of 120 and 60 pixels, and a zero-height tick match the 1.000, 0.500 and 0.000 mWb printed beneath them.<\/figcaption>\n<\/figure>\n\n<h2>Why Is the Net Magnetic Flux Through a Closed Surface Zero?<\/h2>\n\n<p>The net flux out of any closed surface is zero because magnetic field lines never begin or end: every line that enters a closed box leaves it again somewhere else.<\/p>\n\n<p>Electric charges do not behave like this. Put a positive charge inside a closed box and electric field lines stream outwards through the walls, because the charge is where they start; our guide to the <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/electric-field\/\">electric field<\/a> covers that case. Magnetism has no equivalent \u2014 no isolated north pole has ever been found \u2014 so magnetic field lines close on themselves and the books always balance.<\/p>\n\n<p>This is Gauss&#8217;s law for magnetism, and it is one of Maxwell&#8217;s four equations. In words: the total magnetic flux out of any closed surface is exactly zero, always, whatever is inside it. Worked problem 5 checks it on a cube, face by face, and the sum comes to nothing because the two end faces cancel and the four sides contribute zero each.<\/p>\n\n<p>It also explains something you may have noticed about bar magnets. Cut one in half hoping to isolate a pole and you get two shorter magnets, each with a north and a south. The field lines have nowhere to start from.<\/p>\n\n<h2>Where Magnetic Flux Is Actually Measured<\/h2>\n\n<p>Flux earns its keep wherever a surface has to carry a field rather than merely sit in one.<\/p>\n\n<h3>Transformer and motor cores<\/h3>\n\n<p>Iron goes into these machines to give the field an easy route, and the designer has to keep two separate figures in view at once. One is the total flux the magnetic circuit carries, quoted in webers. The other is how hard that flux is being pushed through each square metre of steel, quoted in tesla, because beyond a certain density the iron saturates and stops helping.<\/p>\n\n<p>Dividing the first by the cross-sectional area gives the second, which is this page&#8217;s arithmetic applied to a stack of laminations. The limit itself shifts with the alloy, the lamination thickness and the temperature, so no single number belongs here \u2014 verify before use.<\/p>\n\n<figure style=\"margin:32px auto;max-width:640px;text-align:center;\">\n  <img decoding=\"async\" src=\"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-content\/uploads\/2026\/10\/a-laminated-transformer-core-cut-away-1.webp\"\n       alt=\"Cutaway of a laminated iron transformer core, the surface that carries the magnetic flux through the winding\"\n       loading=\"lazy\"\n       style=\"width:100%;height:auto;border-radius:4px;\" width=\"1920\" height=\"849\">\n  <figcaption style=\"font-size:13px;color:#1F2E47;font-style:italic;margin-top:8px;\">A laminated core. Its cross-section is the area in Phi = B A cos theta, and the iron saturates when the flux density through it gets too high.<\/figcaption>\n<\/figure>\n\n<h3>MRI scanners<\/h3>\n\n<p>An MRI magnet is specified by its flux density, because that is what sets the resonance. The flux matters for everything around it: the force on a steel trolley, the screening the room needs, and the signal picked up by the receiver coils, each of which is a surface with a field through it.<\/p>\n\n<h3>Geomagnetic surveys<\/h3>\n\n<p>A survey instrument reads one component of the Earth&#8217;s field, and tilting it away from the field direction costs exactly the cosine of the misalignment. Run the tilted-loop arithmetic backwards and that tilt drops out of an arccosine, which is what worked problem 4 does.<\/p>\n\n<h3>Checking your own answer<\/h3>\n\n<p>Two quick tests catch most wrong answers without recalculating anything. Compare your flux against the B A ceiling from step three, and treat anything above it as a cosine applied upside down. Then read the unit: webers measure a total and tesla measure a density, so a flux offered in tesla went wrong well before the arithmetic did.<\/p>\n\n<h2>Common Mistakes When Calculating Magnetic Flux<\/h2>\n\n<h3>1. Taking the angle from the loop instead of the normal<\/h3>\n\n<p>This is the big one, and at the 55-degree tilt of worked problem 2 it changes the answer by about 43 per cent. A problem that says &#8220;the loop is tilted at 55 degrees&#8221; is ambiguous unless it says to what. If the 55 degrees is measured from the plane of the loop, the normal is at 35 degrees and the cosine is 0.8192, not 0.5736. Read the question twice and draw the normal.<\/p>\n\n<h3>2. Leaving the area in square centimetres<\/h3>\n\n<p>One square metre is 10,000 square centimetres, not 100 \u2014 the conversion squares. Forget it and your flux is out by four orders of magnitude, which at least makes the mistake easy to spot once you know the milliweber range to expect.<\/p>\n\n<h3>3. Treating a negative flux as an error<\/h3>\n\n<p>A negative flux is a direction, not a mistake. It says the field threads the surface opposite to the normal you chose. The only genuine error here is quoting a sign without ever saying which way the normal points.<\/p>\n\n<h3>4. Expecting a flux to tell you about a current<\/h3>\n\n<p>A steady flux induces nothing at all. It takes a <em>changing<\/em> flux to drive a current, and which way that current runs is <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/lenz-law\/\">Lenz&#8217;s law<\/a>, while the size of the voltage belongs to <a href=\"https:\/\/physicsfundamentalsinfo.com\/blog\/electromagnetism\/electromagnetic-induction\/\">electromagnetic induction<\/a>. Nothing on this page changes with time, so nothing on this page produces a volt.<\/p>\n\n<h2>Worked Problems<\/h2>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 1<\/div><div class=\"pf-problem-question\">A rectangular loop of area 120 cm2 lies square across a uniform magnetic field of flux density 0.45 T, so its normal points along the field. Find the magnetic flux through the loop.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: The surface is flat and the field is uniform, so \u03a6 = B A cos \u03b8. The normal points along the field, so \u03b8 = 0 and cos \u03b8 = 1.\n\nStep 2: Convert the area. A = 120 cm<sup>2<\/sup> \u00d7 10<sup>-4<\/sup> m<sup>2<\/sup>\/cm<sup>2<\/sup> = 0.0120 m<sup>2<\/sup>.\n\nStep 3: Substitute. \u03a6 = 0.45 T \u00d7 0.0120 m<sup>2<\/sup> \u00d7 1 = 5.400 \u00d7 10<sup>-3<\/sup> Wb.\n\n<strong>Answer: 5.40 mWb, or 5.400 \u00d7 10<sup>-3<\/sup> Wb, threading the loop along the normal.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 2<\/div><div class=\"pf-problem-question\">The same 120 cm2 loop in the same 0.45 T field is now tilted so that its normal is 55 degrees from the field. Find the flux. Then find what the answer would have been if the 55 degrees had been measured from the plane of the loop instead, and say which is correct.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Nothing about the field or the loop has changed, so B = 0.45 T and A = 0.0120 m<sup>2<\/sup> as before. Only \u03b8 is new: the normal is 55 degrees from the field, so \u03b8 = 55 degrees.\n\nStep 2: cos 55 deg = 0.5736 to four decimal places. \u03a6 = 0.45 \u00d7 0.0120 \u00d7 0.5736 = 3.097 \u00d7 10<sup>-3<\/sup> Wb.\n\nStep 3: Now the trap. If the 55 degrees had been measured from the loop&#8217;s plane, the normal would be 90 &#8211; 55 = 35 degrees from the field. cos 35 deg = 0.8192 to four places, or 0.819152 to six, and \u03a6 = 0.45 \u00d7 0.0120 \u00d7 0.819152 = 4.423 \u00d7 10<sup>-3<\/sup> Wb. The two answers differ by 1.326 mWb, about 43 per cent of the correct one, and both have perfectly respectable units.\n\n<strong>Answer: 3.097 mWb. The angle in \u03a6 = B A cos \u03b8 is always measured from the normal, so 4.423 mWb is the wrong reading of the question.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 3<\/div><div class=\"pf-problem-question\">A circular loop of radius 4.0 cm sits square on in a uniform field of flux density 0.20 T. Find its area in square metres and the magnetic flux through it.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: The loop is circular, so A = \u03c0r<sup>2<\/sup> with r in metres. r = 4.0 cm = 0.040 m.\n\nStep 2: A = \u03c0 \u00d7 (0.040 m)<sup>2<\/sup> = \u03c0 \u00d7 1.6 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup> = 5.0265 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup>, which is 50.265 cm<sup>2<\/sup>, or 50.27 cm<sup>2<\/sup> to two decimal places.\n\nStep 3: Square on means \u03b8 = 0 and cos \u03b8 = 1, so \u03a6 = 0.20 T \u00d7 5.0265 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup> \u00d7 1 = 1.0053 \u00d7 10<sup>-3<\/sup> Wb.\n\n<strong>Answer: A = 5.0265 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup> and \u03a6 = 1.0053 mWb, which is 1005.3 microwebers.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 4<\/div><div class=\"pf-problem-question\">A flux of 1.8 mWb is measured through a flat coil of area 80 cm2 in a uniform field of flux density 0.30 T. How far is the coil&#039;s normal from the field direction?<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Rearrange. \u03a6 = B A cos \u03b8 gives cos \u03b8 = \u03a6 \/ (B A), so start by finding the largest flux this coil could carry.\n\nStep 2: A = 80 cm<sup>2<\/sup> = 0.0080 m<sup>2<\/sup>, so B A = 0.30 T \u00d7 0.0080 m<sup>2<\/sup> = 2.4 \u00d7 10<sup>-3<\/sup> Wb = 2.4 mWb. That is the flux at \u03b8 = 0, and the measured 1.8 mWb is comfortably below it, so a solution exists.\n\nStep 3: cos \u03b8 = 1.8 mWb \/ 2.4 mWb = 0.7500, and \u03b8 = arccos(0.7500) = 41.4 degrees to one decimal place.\n\n<strong>Answer: 41.4 degrees from the normal. Note that this is the size of the tilt only \u2014 leaning 41.4 degrees either way gives the same flux, so no measurement of flux alone can say which.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 5<\/div><div class=\"pf-problem-question\">A closed cube with faces 50 mm on a side sits in a uniform field of flux density 0.60 T, with the field parallel to one pair of faces&#039; normals. Find the flux through each face and the net flux out of the cube.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Take the normal of every face pointing outwards, which is the convention for a closed surface. Each face is flat and the field is uniform, so \u03a6 = B A cos \u03b8 applies face by face.\n\nStep 2: Every face has A = (0.050 m)<sup>2<\/sup> = 2.5 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup>, which is 25 cm<sup>2<\/sup>. The four side faces have outward normals at right angles to the field, so \u03b8 = 90 degrees, cos \u03b8 = 0 and each carries exactly zero flux.\n\nStep 3: The two end faces are square on. The downstream face has its outward normal along the field, giving \u03a6 = 0.60 T \u00d7 2.5 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup> \u00d7 1 = +1.50 mWb. The upstream face has its outward normal against the field, so cos \u03b8 = -1 and it carries -1.50 mWb. Adding all six: (+1.50) + (-1.50) + 0 + 0 + 0 + 0 = 0.\n\n<strong>Answer: 1.50 mWb through each end face with opposite signs, zero through each of the four sides, and a net flux of exactly zero out of the cube \u2014 Gauss&#8217;s law for magnetism.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 6<\/div><div class=\"pf-problem-question\">The same magnetic flux of 1.2 mWb threads two different flat loops, one of area 30 cm2 and one of area 120 cm2, each square on to the field. Find the flux density at each loop and explain what the comparison shows.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: Square on means cos \u03b8 = 1, so \u03a6 = B A rearranges to B = \u03a6 \/ A.\n\nStep 2: For the small loop, A = 30 cm<sup>2<\/sup> = 3.0 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup>, so B = 1.2 \u00d7 10<sup>-3<\/sup> Wb \/ 3.0 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup> = 0.400 T.\n\nStep 3: For the large loop, A = 120 cm<sup>2<\/sup> = 0.0120 m<sup>2<\/sup>, so B = 1.2 \u00d7 10<sup>-3<\/sup> Wb \/ 0.0120 m<sup>2<\/sup> = 0.100 T. The second loop has four times the area and one quarter the flux density, for the identical flux.\n\n<strong>Answer: 0.400 T and 0.100 T. The flux is the same number in both cases; the flux density is not, because density is flux per unit area \u2014 which is exactly what 1 T = 1 Wb\/m<sup>2<\/sup> says.<\/strong>\n\n<\/div><\/details><\/div>\n\n<div class=\"pf-problem\"><div class=\"pf-problem-num\">Problem 7<\/div><div class=\"pf-problem-question\">Write a magnetic flux of 2.5 mWb in webers, in tesla square metres and in volt seconds. Then find the area of a flat loop that would carry that flux square on in a field of flux density 0.50 T.<\/div><details><summary>Show Solution<\/summary><div class=\"pf-problem-solution\">\n\n<strong>Solution:<\/strong>\n\nStep 1: The milli prefix is 10<sup>-3<\/sup>, so 2.5 mWb = 2.500 \u00d7 10<sup>-3<\/sup> Wb.\n\nStep 2: The weber is a derived unit with two other spellings of the same thing: 1 Wb = 1 T m<sup>2<\/sup> = 1 V s. So the same flux is 2.500 \u00d7 10<sup>-3<\/sup> T m<sup>2<\/sup> and 2.500 \u00d7 10<sup>-3<\/sup> V s. Nothing has been calculated here \u2014 these are three names for one number, and the volt-second form is a unit identity, not an induced voltage.\n\nStep 3: Square on, \u03a6 = B A, so A = \u03a6 \/ B = 2.500 \u00d7 10<sup>-3<\/sup> Wb \/ 0.50 T = 5.0 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup>.\n\n<strong>Answer: 2.500 \u00d7 10<sup>-3<\/sup> Wb = 2.500 \u00d7 10<sup>-3<\/sup> T m<sup>2<\/sup> = 2.500 \u00d7 10<sup>-3<\/sup> V s, carried by a loop of 5.0 \u00d7 10<sup>-3<\/sup> m<sup>2<\/sup>, which is 50 cm<sup>2<\/sup>.<\/strong>\n\n<\/div><\/details><\/div>\n\n<h2>Frequently Asked Questions<\/h2>\n\n<details class=\"pf-faq-item\"><summary>What is magnetic flux in simple terms?<\/summary><div class=\"pf-faq-item-answer\">\n\nMagnetic flux is how much magnetic field passes through a surface. Multiply the flux density by the area of the surface and by the cosine of the angle between the field and the surface&#8217;s normal, and the result is the flux in webers. A loop facing the field square on carries the most; the same loop edge-on carries none at all.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What is the SI unit of magnetic flux?<\/summary><div class=\"pf-faq-item-answer\">\n\nThe weber, symbol Wb. One weber equals one tesla square metre, which is the form every calculation on this page uses, and it also equals one volt second. Practical answers for laboratory-sized loops usually land in milliwebers or microwebers, so a flux of 0.0054 Wb is more readable written as 5.40 mWb.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>What is the difference between magnetic flux and magnetic flux density?<\/summary><div class=\"pf-faq-item-answer\">\n\nFlux density is the field at a point and flux is the total through a surface. The first is measured in tesla, the second in webers, and 1 tesla equals 1 weber per square metre. Spread 1.2 mWb through 30 cm2 and the density is 0.400 T; spread the same flux through 120 cm2 and it drops to 0.100 T.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Why is the angle in the magnetic flux formula measured from the normal?<\/summary><div class=\"pf-faq-item-answer\">\n\nBecause only the part of the field that crosses the surface counts, and the normal is the direction a field has to point in to cross it completely. Measuring from the loop&#8217;s plane gives the complement of the angle you want, which puts a sine where a cosine belongs and turns a square-on loop into a 90-degree reading.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Can magnetic flux be negative?<\/summary><div class=\"pf-faq-item-answer\">\n\nYes, and it simply means the field threads the surface the opposite way to the normal you chose. Past 90 degrees the cosine turns negative and the flux goes with it, reaching the same size as the square-on value, with the opposite sign, at 180 degrees. Flip your choice of normal and every sign flips too.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Why is the net magnetic flux through a closed surface always zero?<\/summary><div class=\"pf-faq-item-answer\">\n\nBecause magnetic field lines have no beginnings and no ends, so whatever enters a closed surface must leave it. There are no magnetic monopoles to act as sources, unlike electric charges. This is Gauss&#8217;s law for magnetism, one of Maxwell&#8217;s four equations, and it holds whatever the shape of the surface and whatever is inside it.\n\n<\/div><\/details>\n\n<details class=\"pf-faq-item\"><summary>Does the shape of the loop change the magnetic flux?<\/summary><div class=\"pf-faq-item-answer\">\n\nNo, only its area and its orientation matter. A circle, a square and a triangle of the same area, all facing a uniform field the same way, carry exactly the same flux. That is why a circular loop problem is really an area problem: work out pi times the radius squared first, then use the ordinary formula without changing anything else.\n\n<\/div><\/details>\n","protected":false},"excerpt":{"rendered":"<p>Magnetic flux is the total magnetic field passing through a surface, Phi = B A cos theta, measured in webers. This guide fixes the one thing that goes wrong most often &#8211; the angle is measured from the normal to the surface, not from the surface &#8211; then works through the weber, flux against flux density, what happens past 90 degrees, and why the net flux out of a closed surface is zero, with an angle table, two original diagrams, seven worked problems and an interactive simulator.<\/p>\n","protected":false},"author":1,"featured_media":2156,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-2149","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electromagnetism"],"_links":{"self":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/comments?post=2149"}],"version-history":[{"count":3,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2149\/revisions"}],"predecessor-version":[{"id":2169,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/posts\/2149\/revisions\/2169"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media\/2156"}],"wp:attachment":[{"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/media?parent=2149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/categories?post=2149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/physicsfundamentalsinfo.com\/blog\/wp-json\/wp\/v2\/tags?post=2149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}